EU Declaration of Conformity

12

EU Declaration of Conformity

Manufacturer

Systemair UAB
Linų st. 101
LT–20174 Ukmergė, LITHUANIA
Office: +370 340 60165

Fax: +370 340 60166

www.systemair.com

The manufacturer hereby confirms that

SAVE VTR 250/B

comply with all applicable requirements in the following
directives and regulations.

Machinery Directive 2006/42/EC

Ecodesign Directive 2009/125/EC

327/2011 Requirements for fans above 125 W
1253/2014 Requirements for ventilation units
1254/2014 Energy labelling of residential ventilation units

Low Voltage Directive 2014/35/EU

EMC Directive 2014/30/EU

RoHS Directive 2011/65/EU, 2015/863/EU

The following harmonized standards are applied in appli-
cable parts:

EN ISO 12100

Safety of machinery - General principles for design - Risk
assessment and risk reduction.

EN 13857

Safety of machinery – Safety distances to prevent hazard
zones being reached by upper or lower limbs.

EN 60204-1

Safety of machinery – Electrical equipment of machines –
Part 1: General requirements.

EN 60335-1

Household and similar electrical appliances – Safety Part
1: General requirements.

EN 60335-2-40

Safety of household and similar electrical appliances -
Part 2-40: Particular requirements for electrical heat
pumps, air-conditioners and dehumidifiers.

EN 50106

Safety of household and similar appliances – Particular
rules for routine tests referring to appliances under the
scope of EN 60 335-1.

EN 60529

Degrees of protection provided by enclosures (IP Code).

EN 62233

Measurement methods for electromagnetic fields of
household appliances and similar apparatus with regard
to human exposure.

EN 61000-6-2

Electromagnetic compatibility (EMC) – Part 6-2: Generic
standards – Immunity for industrial environments.

EN 61000-6-3

Electromagnetic compatibility (EMC) – Part 6-3: Generic
standards – Emission standards for residential, commer-
cial and light-industrial environments.

EN 13053

Ventilation for buildings – Air handling units – Rating and
performance for units, components and sections.

EN 13142

Ventilation for buildings. Components/products for resi-
dential ventilation. Required and optional performance
characteristics

The declaration applies only to product in the condition it
was delivered in and installed in the facility in accordance
with the included installation instructions. The insurance
does not cover components that are added or actions
carried out subsequently on the product.

The complete technical documentation is available.

Ukmergė, 20-02-2021

Nerijus Lapackas
Technical Manager

254496 | v01

Summary of Contents for SAVE VTR 250/B

Page 1: ...Document in original language 254496 v01 SAVE VTR 250 B Installation instructions GB...

Page 2: ...s the rights to alter their products without notice This also applies to products already ordered as long as it does not affect the previously agreed specifications Systemair is not liable or bound by...

Page 3: ...6 4 1 Transport and storage 6 4 2 Delivery Unloading 6 5 Prerequisites for Installation 6 5 1 Location and Space Requirements 7 5 2 Wall preparation for mounting bracket 7 5 3 Outdoor Air Intake Loca...

Page 4: ......

Page 5: ...laim 1 3 Type label Before calling your service representative make a note of the specification and production number from the type label which can be found next to the external connections and inside...

Page 6: ...by an authorized installer and in accordance with local rules and regulations Warning This product is not intended to be used by children or people with reduced physical or mental ability or lack of e...

Page 7: ...Technical Data 3 3 1 Dimensions and Weight Fig 2 Dimensions of left hand unit 254496 v01...

Page 8: ...4 Technical Data Fig 3 Dimensions of right hand unit Water coil connections Drainage The unit weight is 56 kg 254496 v01...

Page 9: ...unit is in tended to be stopped by the user manually or due to calendar function we recommend to install air tight dampers at ex tract and supply air ducts The dampers will ensure that no air circulat...

Page 10: ...d be stored and transported in such a way that it is protected against physical damage It should be covered so dust rain and snow cannot enter and damage the unit and its components Important Use the...

Page 11: ...mended installation location for the outdoor air intake is the northern or eastern side of the building and with a distance to openings for discharge of stale ventilation air kitchen ventilator centra...

Page 12: ...8 Installation C concrete bricks W wood block G gypsum M mineral wool X adaptable height according to needs Make sure the mounting bracket is completely level 254496 v01...

Page 13: ...in moisture damage Do not install the ducts directly against structural building elements to avoid sound propagation Use acoustic insulation and sound attenuators Note The type of ventilation ducts a...

Page 14: ...t temperature sensor units with heater 11 Analog input 5 Freely configurable 12 Digital input 1 Rotor guard sensor only for VSR VTR models 13 Digital input 2 Freely configurable Cooker hood VTR 150 K...

Page 15: ...10 V or a digital input 24 V UI1 default configuration Pressure guard UI2 default configuration Cooker hood UI3 default configuration Fire alarm UI4 default configuration Refresh 24V Maximum current...

Page 16: ...ke modifications Choose heating type or none Reset filter changer timer if necessary Finish startup wizard with OK button All additional changes post startup wizard must be recorded in the Commissioni...

Page 17: ...uct is compliant with the European WEEE Directive and related national waste legislation When disposing the unit follow your local rules and regulations This product packing materials are recyclable a...

Page 18: ...l appliances Part 2 40 Particular requirements for electrical heat pumps air conditioners and dehumidifiers EN 50106 Safety of household and similar appliances Particular rules for routine tests refer...

Page 19: ...254496 v01...

Page 20: ...SAVE VTR 250 B Installation instructions 254496 en_GB 2021 03 22 v01 Systemair UAB Lin st 101 LT 20174 Ukmerg LITHUANIA Phone 370 340 60165 Fax 370 340 60166 www systemair com...

Reviews: