background image

5

installation manual 

Central hole 

Hook hole 

Installation paper board 

Body 

Fixing hole 
 installation paper board 

5

2

3

(H

o

o

k-l

o

ca

ti

o

n

5

7

0

(Bo

d

y) 

6

4

7

(Pa

n

e

l) 

Drain side

(Unit: mm)

545(Hook-location)

570(Body)

647(Panel)

Fig.5-3 

Fig.5-4 

Fig.5-5 

Fig.5-6 

Fig.5-7 

Fig.5-8 

Fig.5-9 

Fig.5-10 

All  the  pictures  in  this  manual  are  for  explanation  
purpose only. They may be slightly different from the  
air 

conditioner 

you 

purchased(depend 

on  

model).The actual shape shall prevail. 

NOTE 

L

 

2 1 

- 0 

6 7 

4

 
3

 

Colourless 

trans parent pipe 

Ceiling 

Body 

Ceiling 

Panel 

Hook 

0 6 

Nut 

Body 

600 

) t 

h g i 

e h   

g n i 

l i 

e c ( 

H

 

Horizontal 

indicator 

4 5 

5.3   Install The Panel 

Remove the air-in grill. 

Never  put  the  panel  face  down  on  floor  or  against  the  
wall, or on uneven surfaces.

Never crash or strike it. 

Slide  two  grill  switches  toward  the  middle  at  the  same  time,  
and then pull them up.  

(Refer to Fig.5-9) 

Draw  the  grill  up  to  an  angle  of  about  45,  and  remove  it.  

(Refer to Fig.5-10) 

CAUTION 

Screw M5x16 
(Accessory) 

Grid switch 

The installation cover of the swing motor must sink into  
the corresponding water receiver. 

Install the panel 

Align the swing motor on the panel to the tubing joints of the  
body properly.  

( Refer to Fig.5-11) 

Hang  the  four  fixed  rope  of  the  main  body  to  the  installation  
cover  and  the  other  three  covers  of  the  swing  motor:  

(Refer 

to Fig.5-11  and  ) 

CAUTION 

6

0

 

Summary of Contents for SYSVRF CASSETTE MINI

Page 1: ...SYSVRF CASSETTE MINI Cassette 600x600 VRF indoor unit INSTALLATION MANUAL GB...

Page 2: ...use injury The appliance must be installed 2 3m above floor The appliance shall not be installed in the laundry Before obtaining access to terminals all supply circuits must be disconnected The applia...

Page 3: ...liquid evaporating Other special conditions Carry out the specified installation work after taking into account strong winds typhoons or earthquakes Improper installation work may result in the equipm...

Page 4: ...without further notices Cautions on remote controller installation Remote controller Remote controller holder Mounting screw B ST2 9x10 C H This manual Four way Cassette Four way Cassette compact INST...

Page 5: ...main body from the four sides or diagonal line direction the lever indicator also can check the lever from four sides of the main body Refer to Fig 5 6 Locate the air conditioner firmly by wrenching...

Page 6: ...i e h g n i l i e c H Horizontal indicator 45 5 3 Install The Panel Remove the air in grill Never put the panel face down on floor or against the wall or on uneven surfaces Never crash or strike it Sl...

Page 7: ...rant oil and wrench it for 3 4rounds with hands before fasten the flare nuts Refer to Fig 6 1 Be sure to use two wrenches simultaneously when you connect or disconnect the pipes The stop valve of the...

Page 8: ...or or soap water Cover the joint of the connecting pipe to the indoor unit with the sound proof insulating sheath fittings and bind it well with the tapes to prevent leakage Flaring Cut a pipe with a...

Page 9: ...76cmHg Loosen and remove the square cover of stop valves A and B to open stop valve A and B completely then fasten them Disassemble the charge hose from the repair mouth of stop valve A and fasten the...

Page 10: ...s should be incorporated in the fixed wiring according to the National wiring regulation Be sure to locate the power wiring and the signal wiring well to avoid cross disturbance and their contact with...

Page 11: ...ng Regulation Ground the air conditioner properly to obtain a good anti interference effect CAUTION Model W 1500 5600 15 15 3 2 0 Circuit breaker fuse A Indoor unit power wiring mm2 Indoor outdoor con...

Page 12: ...ation 1 means factory test mode 0 means add auto searching mode default setting 1 means DC fan is chosen 0 means AC fan is chosen 00 means DC fan static pressure is 0 reserved 01 means DC fan static p...

Page 13: ...f COOLING with the remotecontroller andcheckthefollowingpointsperthe Owner s Manual If there is any malfunction please resolve it as per chapter Troubles And Causes The indoor unit Whether the switch...

Page 14: ...SYSVRF CASSETTE MINI_IM EN April 2014 MDV11I 025EW...

Reviews: