Introduction
Smoke gas fan ZRS from Systemair is used to prevent insufficient draft from stoves, ovens and fire-
places. The smoke gas fan can be installed without interfering with the chimney pipe.
Transport and storage
All Systemair fans are packaged at the factory to withstand normal transport handling.
When handling the goods use suitable lifting equipment in order to avoid damage to fans or personnel.
The fans do not have any lifting eye bolts.
Avoid blows or shock loads.
Be on the alert for any damage on the packaging or the fan.
The fans should be stored in a dry area protected from the weather and dirt until final installation.
Avoid excessive storage periods (we recommend one year maximum).
Note!
Do not lift the fan by the connecting cable, connection box, impeller or inlet cone.
Safety information
Systemair fans are not ready-to-use products and are only to be put into operation after they have been
built into machines, duct systems or if safe operation has been ensured by a contact protection grid.
Installation must be carried out in such a way that direct contact with moving parts is not possible.
Installation has to be performed by authorized personnel only!
The fans must not be used in an explosive atmosphere. Connect to a flue duct, max. temperature 200°C.
The fans must be installed so that safe operation and maintenance is ensured. Safety devices (e.g.
motor protection, contact protection grid etc), must not be dismantled, circumvented or made
inoperative.
Note!
Before servicing or maintenance, switch off power, (all-pole circuit breaker), and make sure the
impeller has come to a standstill.
Note!
The fans can have sharp edges and corners which may cause injuries.
Note!
The smoke gas fan must always be running when the fireplace is being used.
Installation
Put the insulation carpet, supplied with the fan, on top of the chimney and cut out a hole for the fan.
Fixate the four adjustable steering rods which are pushed into the chimney (no need to interfere with the
chimney itself).
The supplied steel wire can be used as extra support during chimney sweeping.
Installation, electrical connection and commissioning are only to be performed by authorized personnel
and in accordance with the requirements of the installation.
Electrical connection according to the wiring diagram in the terminal box, markings on terminal blocks or
on cable.
Use a dummy plug seal for the compression gland fitting as well.
The fan must be installed so that vibrations are not transmitted to duct systems or frame of building.
Make sure the assembly of the fan is firmly fixed and stable.
The fans must be assembled so that service and maintenance can be performed easily and safely.