background image

RiseAtlas450T/625T is a safe and easy-to-use stationary ceiling lift unit which can be used in all settings and in all types 
of rooms, both on permanent rail systems and on portable, freestanding lift stands. When used with the appropriate  
lifting accessories, RiseAtlas450T/625T provides secure, comfortable and individually adapted lifting of users in  
connection with seated or horizontal transfers to and from the bed, wheelchair or toilet. RiseAtlas450T/625T offers a 
large lifting area and the possibility of both very low and very high lifting, making it an excellent solution also for lifting 
from the floor and for gait training and standing training. RiseAtlas450T/625T can also be used for convenient transfer of 
users from one room to another. RiseAtlas450T/625T with SmartPark-function is equipped with a built-in transfer motor. 
The SmartPark-function allows the lift unit to be returned to the parking place and charging position with a simple touch 
of the hand control. 

Manual nr: 708-En   Ver. 

6

   150504

User manual - English

SWL:
RiseAtlas450T: 205 kg/450 lbs
RiseAtlas625T: 285 kg/625 lbs

50100052 (RiseAtlas450T)
50100053 (RiseAtlas625T)

RiseAtlas450T/RiseAtlas625T

with SmartPark-function

Visual inspection 

Inspect lift functions regularly. Check to ensure that product is free from damage. 

Before use

Ensure that the product is correctly mounted in the trolley.
Check rail end stops.
Check sling bar connection and safety latch function.
Check lifting movement.
Inspect the lift for signs of wear and damage.
Check the hand control cable for signs of wear.
Check to ensure that hand control markings coincide with lift functions.
Check battery charge level.

Always read the user manuals for all assistive devices used during a transfer.
Keep the user manual where it is accessible to users of the product.
Under no circumstances may the lift be used by persons who have not received instruction in the operation of the lift.  
It is strongly prohibited to modify the original product.

 Functional inspection

Always read the user manual

System

RoMedic

TM

Summary of Contents for 50100052

Page 1: ...charging position with a simple touch of the hand control Manual nr 708 En Ver 6 150504 User manual English SWL RiseAtlas450T 205 kg 450 lbs RiseAtlas625T 285 kg 625 lbs 50100052 RiseAtlas450T 5010005...

Page 2: ...e use 7 Safe working load 8 Description of functions and symbols 8 Charging the lift unit 9 SmartPark function 10 Hand control 11 Information panel 12 Preventive service maintenance 12 Emergency stop...

Page 3: ...least 3 hours before it is used for the first time The lift unit is shipped with the fuse removed Prior to installation the cover is removed and a 20A fuse is inserted The fuse is packed in a bag As s...

Page 4: ...emergency stop strap is cut at a height where the strap doesn t interfere with a normal lifting situation but at the same time is easily reached by all users The strap is cut with scissors and singed...

Page 5: ...the right side according to fig 3 4 Mount charger contacts according to fig 4 NOTE Push the charger contact A in about 50 mm if only a stop bolt is used When an adjustable end stop is used the charge...

Page 6: ...ifting sling At the same time check both the user manual and electrical emergency lowering function with someone in the lift See section on Emergency lowering Check to ensure that the rail system is e...

Page 7: ...unattended in a lifting situation Warranty does only apply if repairs or alterations are made to the lift by personnel who are authorized RiseAtlas must not come in direct contact with water RiseAtla...

Page 8: ...the functions that are available for caregivers and users Symbols on the product Battery status Emergency stop The lift requires service or maintenance Directional indication transfer motor Overload W...

Page 9: ...e current battery status Only hand control charging or end point charging mode Charging indication hand control charging and end point charging When the hand control is placed in the charger station 2...

Page 10: ...he parking position When the lift unit has stopped at the parking position the slingbar will be lowered to the height that was selected before the SmartPark function was activated Safety Before activa...

Page 11: ...done the battery symbol on the lift unit s information display is lit for 2 seconds showing the current battery status If the battery symbol does not light and the lift unit is not activated check tha...

Page 12: ...load protection which prevents the lift from lifting more than the maximum rated load if this happen A symbol for overload and a warning triangle light up and a signal is heard If this symbol is activ...

Page 13: ...upplied Allen key in the hole as indicated fig 4 Turn it counter clockwise to lower and clockwise to raise the sling bar Always ensure that emergency lowering is done in an appropriate location NOTE L...

Page 14: ...l If the lift cannot be run down check to ensure that load is applied to the lift strap that the battery symbol does not indicate low battery charge level that the directional indicators on the button...

Page 15: ...lingBar two point sling bar SlingBarSpreader M side bars can be used as an accessory SlingBarSpreader M open up the lifting sling and provide for a more reclined position SlingBar XS 250 mm article no...

Page 16: ...ents containing phenol or chlorine as this could damage the aluminium and the plastic materials If disinfection is needed 70 ethanol 45 isopropanol or similar should be used Storage and transportation...

Page 17: ...Unload 55 dB Max load 57 dB Hand control Electronic Emergency lowering Manual and electrical Lifting range 2400 mm 95 inch Lift weight 7 2 kg 15 9 lbs IP class lift unit IP 20 IP class hand control I...

Page 18: ...cal emergency lowering 5 Manual emergency lowering raising inside cover 6 Control panel A Rail 6 4 16 0 cm 2 5 6 2 inch B Lift unit overall height 16 0 cm 6 2 inch C Installation height 23 0 cm 9 inch...

Page 19: ...19 M A N U A L SystemRoMedic TM...

Page 20: ...vironment and quality of care and at the same time achieves significant cost savings Always make sure that you have the correct version of the manual The most recent version of all manuals are availab...

Reviews: