Using the Command Line Interface (CLI)
SYSTIMAX® AirSPEED™ AP542
User Guide
172
Ethernet Interface Parameters
Management Parameters
Secure Management Parameters
SNMP Parameters
Name
Type
Values
Access
CLI Parameter
Ethernet Interface
Group
N/A
R
ethernet
Speed
Integer
10halfduplex
10fullduplex
10autoduplex
100halfduplex
100fullduplex
autohalfduplex
autoautoduplex (default)
RW
etherspeed
MAC Address
PhyAddress
N/A
R
ethermacaddr
Name
Type
Values
Access
CLI Parameter
Secure Management
Integer
enable/disable
RW
securemgmtstatus
Name
Type
Values
Access
CLI Parameter
SNMP
Group
N/A
R
snmp
SNMP Management Interface
Bitmask
Interface
Bitmask
0 or 2 = No interfaces (disable)
1 or 3 = Ethernet
4 or 6 = Wireless A
8 or 10 = Wireless B
12 = Wireless A & B
13 or 15 = All interfaces (default is
15)
RW
snmpifbitmask
Read Password
DisplayString
User Defined
public (default)
6 - 32 characters
W
snmprpasswd
Read/Write Password
DisplayString
User Defined
public (default)
6 - 32 characters
W
snmprwpasswd
SNMPv3 Authentication Password
DisplayString
User Defined
public (default)
6 - 32 characters
W
snmpv3authpasswd
SNMPv3 Privacy Password
DisplayString
User Defined
public (default)
6 - 32 characters
W
snmpv3privpasswd