Using the Command Line Interface (CLI)
SYSTIMAX® AirSPEED™ AP542
User Guide
173
HTTP (web browser) Parameters
NOTE
The default path for the Help files is
C:/Program Files/AirSPEED/AP542/HTML/home.htm
. (Use the forward
slash character ("/") rather than the backslash character ("\") when configuring the
Help Link
location.)
Telnet Parameters
Serial Port Parameters
Name
Type
Values
Access
CLI Parameter
HTTP
Group
N/A
R
http
HTTP Management Interface
Bitmask
Interface
Bitmask
0 or 2 = No interfaces (disable)
1 or 3 = Ethernet
4 or 6 = Wireless A
8 or 10 = Wireless B
12 = Wireless A & B
13 or 15 = All interfaces (default is
15)
RW
httpifbitmask
HTTP Password
DisplayString
User Defined
6 - 32 characters
W
httppasswd
HTTP Port
Integer
User Defined
Default = 80
RW
httpport
Help Link
DisplayString
User Defined
RW
httphelplink
SSL Status
Integer
enable/disable
RW
sslstatus
SSL Certificate Passphrase
DisplayString
User Defined
W
sslpassphrase
Name
Type
Values
Access
CLI Parameter
Telnet
Group
N/A
R
telnet
Telnet Management Interface
Bitmask
Interface Bitmask
0 or 2 = No interfaces (disable)
1 or 3 = Ethernet
4 or 6 = Wireless A
8 or 10 = Wireless B
12 = Wireless A & B
13 or 15 = all interfaces (default is
15)
RW
telifbitmask
Telnet Port
Integer
User Defined
23 (default)
RW
telport
Telnet Login Inactivity Time-out
Integer
30 – 300 seconds
60 sec (default)
RW
tellogintout
Telnet Session Idle Time-out
Integer
60 - 36000 seconds
900 sec (default)
RW
telsessiontout
Name
Type
Values
Access
CLI Parameter
Serial
Group
N/A
R
serial
Baud Rate
Integer
2400, 4800,
9600 (default),
19200, 38400, 57600
RW
serbaudrate
Data Bits
Integer
8
R
serdatabits
Parity
Integer
none
R serparity
Stop Bits
Integer
1
R
serstopbits
Flow Control
Value
none (default)
xonxoff
RW
serflowctrl