21
RS 232
Interface for firmware upgrades
In a
R-System the connection to a home automation system is
accomplished through the RS 232 Interface (type MRA/C-K which is available
as an optional accessory).
If the
MP 1260 R
is operated outside a
R-System, this interface can also
be used for control of the
MP 1260 R
– for example in combination with a
CRESTRON or AMX home automation system.
To enable device control via the RS232 interface, the
MP 1260 R
must be
equipped with a special firmware. A description of the control interface and the
control protocol can be found in the download section of the
website
(http://www.taelektroakustik.de).
RC-IN
Control input for older
systems with RC control interface.
Connect this socket to the control output of your
amplifier – eg. The AUX1
control output (see chapter
'
Appendix A, Wiring diagram:
MP 1260 R
in a
system with RC control
'
).
If your
amplifier or receiver is equipped with a
R
LINK
control output,
please use the
R
LINK
control. In this case the RC-IN socket may not be used.
Direct remote control with remote control set FBS6a (optional accessory)
If the
MP 1260 R
shall be operated ‚stand-alone‘ outside a
system, the
remote control receiver type
E2000
from the remote control set FBS6a can be
conected to the RC-IN socket.
R
LINK
Control input / output for
R
LINK
– systems:
Both sockets are equivalent – one is used as input, the other one serves as
output towards other
R
LINK
devices
(see chapter
'
Appendix A, Wiring diagram:
MP 1260 R
in a
system with
R
LINK
control
'
).
Mains input
The mains cable is plugged into this socket.
For correct connections refer to the sections
'
Installation and wiring
'
and
'
Safety notes
'
.
Mains switch
Not present on all model variants (depending on national safety rules).
For operation the mains switch (if present) is to be switched to the position
marked 'I'.