background image

Safety Instructions

 

WARNING

Please keep this User Guide for future consultation. If you sell the unit to another user, be sure 

that they also receive this instruction booklet

Unpack and check carefully there is no transportation damage before using the unit.

Before operating, ensure that the voltage and frequency of power supply match the power 

requirements of the unit.

It's important to ground the yellow/green conductor to earth in order to avoid electric shock.

The unit is for indoor use only. Use only in a dry location.

The unit must be installed in a location with adequate ventilation.  Be sure that no ventilation 

slots are blocked. 

Disconnect main power before fuse replacement or servicing. 

Replace fuse only with the same type. 

In the event of serious operating problem, stop using the unit immediately. Never try to repair 

the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. 

Please contact the nearest authorized technical assistance center. Always use the same type 

spare parts.  

Don't connect the device to any dimmer pack.

Do not touch any wire during operation as high voltage might be causing electric shock.

 

Please read carefully the instructions, which 
includes important infromation about the 
installation, usage and maintenance.

 

Summary of Contents for Proline 1300

Page 1: ...Bedienungsanleitung user manual Proline 1300 Proline 1800 Proline 2700 Proline 3000 ...

Page 2: ...nktionen am Gerät verursachen Bitte wenden Sie sich im Servicefall an Ihren Händler Verwenden Sie immer Ersatzteile gleichen Typs Schließen Sie das Gerät nicht an einen Dimmer an Berühren Sie während des Betriebs keine Drähte Es besteht die Gefahr eines Stromschlages Entsorgen Sie Verpackungsmaterial immer gemäß den örtlichen Bestimmungen Lesen Sie dieses Handbuch und die f o l g e n d e n S i c h...

Page 3: ...halten Sie die Endstufe sofort aus beheben Sie den die Fehler und schalten Sie die Endstufe wieder ein 5 LED für Stereo mode grün Leuchtet wenn das Gerät im Stereo Modus betrieben wird 6 LED für Bridge mode grün Leuchtet wenn das Gerät im Bridge Modus betrieben wird 7 LED für Parallel mode grün Leuchtet wenn das Gerät im Parallel Modus betreiben wird 8 CHA CHB Signal LEDs grün Zeigt den ordnungsge...

Page 4: ...eeve Masse 5 Mode selector Wählen Sie hier den gewünschten Betriebsmodus Stereo Bridged Parallel 6 CHASpeakonAusgang Standard Speakon Buchse pos 1 2 neg 1 2 7 CHB SpeakonAusgang Standard Speakon Buchse pos 1 2 neg 1 2 8 BRIDGE SpeakonAusgang Standard Speakon Buchse pos 1 2 neg 1 2 9 Ground Lift Schalter Trennt die Signalmasse ab Schalten Sie den Schalter auf LIFT um Masseschleifen zu unterbinden 1...

Page 5: ...0W 3000W Frequenzbereich Input sensitivity S N ratio 95dB 90dB 98dB 100dB Slew rate 15V us 18V us 21V us 22V us Damping factor 450 500 600 700 Schutzeinrichtungen LED Kühlsystem Anschlüsse 550W 850W 1250W 1550W Spannung Abmessungen Gewicht 26 31 5 36 37 20 Hz 20kHz 1 5dB 0 77V Crosstalk at rated output 8 ohms 1kHz 70dB Kurzschluss Strombegrenzung Gleichspannungsschutz Netzsicherung Temperatur Soft...

Page 6: ...e installed in a location with adequate ventilation Be sure that no ventilation slots are blocked Disconnect main power before fuse replacement or servicing Replace fuse only with the same type In the event of serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact th...

Page 7: ...el control so that the Peak LED turns off B As the signal has been input the Peak LED lights continuously but the speaker has no voice it is possibly that it is short circuited for loading You should turn off the amplifier Find out where the trouble is and renew operation 5 Stereo mode indicating LED green This LED will be on when working under Stereo mode 6 Bridge mode indicating LED green This L...

Page 8: ...ck Tip signal Ring signal Sleeve ground 5 Mode selector For Stereo Bridge or Parallel mode selection 6 CHASpeakon output connector standard Speakon connector pos 1 2 neg 1 2 7 CHB Speakon output connector standard Speakon connector pos 1 2 neg 1 2 8 BRIDGE Speakon output connector standard Speakon connector pos 1 2 neg 1 2 9 Ground Lift switch Setting the amplifier to be grounded or lifted 10 Powe...

Page 9: ...Input sensitivity S N ratio 95dB 90dB 98dB 100dB Slew rate 15V us 18V us 21V us 22V us Damping factor 450 500 600 700 Protection LED Cooling system Connection 550W 850W 1250W 1550W Power Dimension WxDxH Weight kg 26 31 5 36 37 200 240V AC 50 60Hz 482x430 5x132mm Input bal XLR and 1 4 jack Output Speakon Power Consumption halfpower 8 ohms Short circuit current limited DC fault AC line fuse thermal ...

Page 10: ... i l d i e s e r A n l e i t u n g d a r f e g a l a u f w e l c h e W e i s e o h n e s c h r i f t l i c h e G e n e h m i g u n g d e s M u s i k h a u s T h o m a n n v e r v i e l f ä l t i g t w e r d e n T e c h n i s c h e Ä n d e r u n g e n v o r b e h a l t e n R 080904 KR ...

Reviews: