INSTRUCTION
MANUAL
24
8.3.2 COLLARING WITH PLUS 115
1. Place the PLUS 115 unit on top of the
base plate assembly so that the locking pins
underneath the unit match the four holes in the
base plate assembly.
Turn the unit counter-clockwise so that it locks.
You may also place the PLUS 115 unit
sideways to 90° increments, so you have
four different collaring positions available to
the same point.
1
Turn the locking lever (1) to lock the PLUS 115
unit to base plate.
2. Lubricate the forming pins of the collaring
head and retract the pins into the shank. Place
the collaring head into the PLUS 115 unit so
that the keys of the collaring head lock into the
grooves inside the PLUS 115.
Turn clockwise only!
3. Let the collaring head drop to the collaring
start position by rotating the adapter
counterclockwise by hand.