PORTABLE
COLLARING SYSTEM
27
PLUS 115
8.4 FACING
1. Adjust the wanted facing height. The adjustment is made by rotating the facing tool
handwheel to the wanted scale reading. To do that you have to loosen the locking wheel
under the handwheel. After the adjustment, tighten the locking wheel.
2. Lubricate the facing tool blade.
Place the facing tool inside the PLUS 115 unit
and turn the cover into the locking position.
NOTE!
¨
Make sure that the facing tool blade is rotated up enough before
placing it inside the PLUS 115 unit.
3.
Turn the speed selector knob on the T-65 to position II. Start the drill by pressing the foot
pedal and rotating the facing tool handwheel in clockwise direction. Rotate the handwheel
smoothly as far as it will go.
Stop the T-65 and rotate the facing tool blade up for the next collar.
4. Detach the power cord from the T-65 machine and remove T-65 from the PLUS-115 unit.
Take the facing tool out from the PLUS 115 unit.
5. Remove the PLUS 115 unit from the base plate by turning the locking lever. Loosen the
ring clamp locking levers, open the ring clamps and remove the base plate from the tube).