Total no. of pages: 30
PAGE 19
Anleitung EAG80_26_00_2017_03_28_GB
Version 28.04.2017
4.4
WAAGE
Waage
Waage
AUFLo
Display steps
⇑
⇓
Stabe
Weighing elements basic settings
⇑
⇓
nuLLp
Set scales to zero
⇑
⇓
FACTO
Weight factor
⇑
⇓
0
-
JUS
Zero point adjustment
⇑
⇓
JUST
Scales adjustment with weights
⇑
⇓
4.4.1
AuFLo
Auflo
Selection of display steps 0,01; 0,02; 0,05; 0,1; 0,2; 0,5; 1; 2; 5; 10; 20; 50
4.4.2
StAbE
Stabe
Basic settings of weighing elements , adjustment via key data (quantity / max load / mV/V)
StAbA quantity of connected weighing elements
LASt maximum load of connected weighing elements (see type plate of weighing element)
StAbS mV/V value of connected weighing element (see type plate of weighing element)
4.4.3
nuLLP
NULLP
Set scales to 0 when zero button is activated
4.4.4
Facto
FaCTO
Input of weight factor
4.4.5
0-JUS
0
-
jUs
0-point adjustment for better readjustment with high dead load
4.4.6
JUSt
JUST
Scales adjustment with weights
0-JuS
0-point adjustment
G-JuS
Weight entry for adjustment