3. Technical Data
Model
Garten-Jet 750
Garten-Jet 1200
Mains voltage / frequency
230 V ~ 50 Hz
230 V ~ 50 Hz
Nominal performance
600 Watt
1,200 Watt
Protection type
IP X4
IP 44
Suction port
30.93 mm
(1 “)
, female
30.93 mm
(1 “)
, female
Pressure port
30.93 mm
(1 “)
, female
30.93 mm
(1 “)
, female
Max. flow rate (Q
max
)
1)
2,800 l/h
4,300 l/h
Max. pressure
4.2 bar
5.0 bar
Max. delivery height (H
max
)
1)
42 m
50 m
Max. suction height
9 m
9 m
Max. size of the solids being pumped
3 mm
3 mm
Max. permissible operating pressure
6 bar
6 bar
Min. ambient temperature
5 °C
5 °C
Max. ambient temperature
40 °C
40 °C
Min. fluid temperature
2 °C
2 °C
Max. fluid temperature (T
max
)
35 °C
35 °C
Max. cut-in frequency in one hour
40, evenly distributed
40, evenly distributed
Length of connection cable
1.5 m
1.5 m
Cable type
H07RN-F
H07RN-F
Weight (net)
7.9 kg
15.5 kg
Guaranteed sound power level (L
WA
)
2)
68 dB
86.4 dB
Measured sound power level (L
WA
)
2)
65.3 dB
84.9 dB
Sound pressure level (L
pA
)
2)
59.7 dB
76.9 dB
Dimensions (L x D x H)
35 x 15 x 23 cm
42 x 19 x 25 cm
Item no.
31175
31174
1)
2)
The values were determined with free, unreduced in- an outlet.
Noise emission values obtained according to the EN 12639 regulation. Measurement method according to
EN ISO 3744.
4. Scope of delivery
The scope of the delivery of this product includes:
One pump with connection cable, one operating manual. Please verify that the scope of delivery is complete.
Depending on the purpose of the application, additional accessories may be necessary (please refer to the
chapters titled "Installation", "Automation with special accessories” and “How to order spare parts“).
If possible, keep the packing until the warranty period has expired. Please dispose of the packing materials in an
environmental-friendly manner.
5. Installation
5.1.
General installation information
During the entire process of installation, the device must not be connected to the electrical
mains.
The pump should be installed in a dry place with an ambient temperature not to exceed 40 °C
and not to fall below 5 °C. The pump and the entire connection system have to be protected
from frost and other climatic influences.
9
Summary of Contents for Garten Jet 750
Page 46: ...1 T I P 1 1 2 1 3 2 4 2 5 3 6 4 7 4 8 5 9 6 10 7 11 7 12 8 1 8 2 T I P 43...
Page 48: ...3 5 5 1 40 C 5 C Teflon Teflon 5 2 2 1 HA 4 m 25 3 4 0 3 m HI 5 3 11 5 6 7 5 4 45...
Page 50: ...5 8 8 9 2 T I P GP 7 230V AC on off on off T I P GP 8 www tip pumpen de 47...
Page 52: ...7 3 1 2 3 4 1 GS 2 3 4 4 1 2 2 2 1 2 2 2 10 1 2 3 11 www tip pumpen de 49...
Page 53: ...8 12 2002 96 EC 50...
Page 82: ...1 T I P 1 1 2 1 3 2 4 2 5 2 6 4 7 4 8 5 9 5 10 6 11 7 12 7 1 8 2 T I P T I P 79...
Page 85: ...4 6 Fl 30 mA DIN VDE 0100 739 VDE H07RN F 3 x 1 0 mm 7 82...
Page 86: ...5 8 8 9 2 T I P GP 7 230 V T I P GP 8 www tip pumpen de 9 10 83...
Page 88: ...7 a 1 2 3 11 www tip pumpen de 12 EU EU 2002 96 EK 85...
Page 115: ...1 T I P 1 1 2 1 3 2 4 2 5 2 6 4 7 4 8 5 9 5 10 6 11 7 12 7 1 8 2 T I P 112...
Page 117: ...3 40 C 5 C 5 2 2 1 HA 4 25 3 4 0 3 HI 5 3 11 5 6 7 5 4 T I P 30943 5 5 114...
Page 118: ...4 FI 30 mA DIN VDE 0100 702 und 0100 738 2 6 FI 30 DIN VDE 0100 739 H07RN F 3 x 1 0 VDE 7 115...
Page 119: ...5 8 9 8 2 T I P GP 7 230 T I P GP 8 www tip pumpen de 9 10 116...
Page 120: ...6 1 1 2 3 4 1 2 3 4 2 1 2 3 1 2 a b c d 3 3 1 2 3 4 1 2 3 4 4 1 2 2 2 1 2 2 2 10 117...
Page 121: ...7 1 2 3 11 www tip pumpen de 12 2002 96 E 118...
Page 122: ...1 T I P 1 1 2 1 3 2 4 2 5 2 6 4 7 4 8 5 9 5 10 6 11 7 12 7 1 8 2 T I P T I P 119...
Page 125: ...4 6 FI 30 DIN VDE 0100 739 H07RN F 3 x 1 0 VDE 7 122...
Page 126: ...5 8 9 8 2 T I P GP 7 230 T I P GP 8 www tip pumpen de 9 10 1 1 2 3 4 1 2 3 4 123...
Page 127: ...6 2 1 2 3 1 2 a b c d 3 3 1 2 3 4 1 2 3 4 4 1 2 2 2 1 2 2 2 10 1 2 3 124...