4
Model
HWA 6000 EPF
Min. ambient temperature
5 °C
Min. fluid temperature
2 °C
Max. fluid temperature (Tmax)
35 °C
Max. cut-in frequency in one hour
40, evenly distributed
Length of connection cable
1.5 m
Cable type
H07RN-F
Weight (net)
ca. 13.2 kg
Guaranteed sound power level (LWA) 2)
82 dB (A)
Measured sound power level (LWA) 2)
80.6 dB (A)
Sound pressure level (LpA) 2)
67.9 dB (A)
Dimensions (L x D x H)
48.5 x 24.5 x 29.0 cm
Article no.
30198
1)
2)
The values were determined with free, unreduced in- an outlet.
Noise emission values obtained according to the EN 12639 regulation. Measurement method ac-
cording to EN ISO 3744.
5. Installation
5.1.
General installation information
During the entire process of installation, the device must not be con-
nected to the electrical mains.
The pump should be installed in a dry place with an ambient tempera-
ture not to fall below 5 °C. The pump and the entire connection system
have to be protected from frost and other climatic influences.
When installing the device, please make sure that the motor is suffi-
ciently ventilated.
All connection lines have to be perfectly tight since leaking lines may affect the
performance of the pump and cause considerable damage. Therefore, please
use Teflon tape to seal the
contact surfaces between the
threaded sections of the lines
and the connection with the
pump (Fig.1). This use of seal-
ing material such as Teflon
tape is the only way to ensure
an airtight assembly.
Avoid when tightening screw
excessive force that may
cause damage. When laying the connection pipes, you should make sure that
the pump is not exposed to any form of weight, vibration or tension. Moreover,
the connection lines must not contain any kinks or an adverse slope.