2
2. Range of use
The TLS 100 E anti-dry-running feature is an electronic flowswitch with an adjustable cut-out timer used as a
protective feature to prevent electrical pumps, domestic booster sets and similar devices from running dry in the
absence of water.
Upon power-up, the TLS 100 E will activate the electrical pump and keep it running as long as a specific quantity
of flowing liquid is present inside the line. As soon as the water flow inside the line ceases, the electronic
monitoring device will activate a timer which will cause the pump to cut out after the lapse of a specific, adjustable
period of time.
The activation of the time is indicated by the flashing of the red indicator lamp. As soon as the set time span has
elapsed, the device will check whether the downstream pump is still consuming a specified amount of electrical
power. If the required current strength is less than 1 Ampère, the device will switch to “standby” mode, and the
pump is ready to return to operation at any time. If after the lapse of the specified time window the demanded
current strength is above one Ampère, the TLS 100 E will interrupt the flow of current to the pump and switch to
the “error” condition. This condition is indicated by the uninterrupted lighting of the red indicator lamp.
Resuming the pump's operation is impossible without pressing the reset key on the TLS 100 E. Before that,
please be sure to remove the cause of the dry-running of the connected pump.
This product is intended for private use in the home area and not for commercial or industrial purposes.
The TLS 100 E anti-dry-running feature is not suitable for pumps with a power consumption of
less than 230W.
3. Technical Data
Model
TLS 100 E
Mains voltage / frequency
230 V ~ 50 Hz
Max. current strength for connection socket
12 A
Minimum current strength of the downstream pump under load. 1 A
Protection type
IP44
Intake port
30.93 mm
(1 “)
, female, rotating
Outlet port
33.25 mm
(1 “)
, male
Max. permissible operating pressure
10 bar
Timer setting range
10 – 180 seconds
Timer ex-factory setting
180 seconds
Max. fluid temperature
55° C
Connection cable
1.25 m
Cable type
H05RN-F
Weight (net)
0.75 kg
Dimensions (L x D x H)
11 x 12 x 14.5 cm
Item no.
302915
4. Scope of delivery
The scope of the delivery of this product includes:
One electronic anti-dry-running feature with a connection cord, one operating manual.
Please verify that the scope of delivery is complete. Depending on the purpose of the application, additional
accessories may be necessary (please refer to the chapters titled "Installation" and “How to order spare parts“).
If possible, keep the packing until the warranty period has expired. Please dispose of the packing materials in an
environmental-friendly manner.
5. Installation
5.1.
General installation information
During the entire process of installation, the devices must not be connected to the electrical
mains.
The TLS 100 E has to be installed in an upright position. The arrow on the casing cover lid has
to point upwards.
8