background image

 

www.scalesearch.co.uk 

SECTION 3    OPERATION                                                                             

 

3. 1 GENERAL INSTRUCTION 

1

Please read this manual carefully before you operate the hanging scale. 

2.    When battery goes low, the BATT icon will be display. It is the time to charge 

the battery with the special charger.   

3

If  you  will let 

DR

  hanging  scale  deactivate  for  a long  time,  please  note  you 

also need change the battery every three months 

 

3.  2 BASIC OPERATION

 

3.2.1    Power on and off 
                Please  press 

ON/OFF

  key  before  you  operate  this  scale,  and  press 

ON/OFF

 

                key again after you operate this scale 
3.2.2    Zero the scale 

When  there  is  no  item  on  the  scale  but  reading  is  not  zero,  press  the 

ZERO

      key to make re-zero reading. 

3.2.3    Reading lock 

When  reading  is  not  stable,  you  can  use 

HOLD

  key  to lock  reading,  so 

you  can  read  easily,  after  you  read,  press 

HOLD

  key  again  to  return 

normal weighing mode. 

3.2.4    Overload Warning 

Please  do  not  add  item  that  is  over  the  maximum  capacity.    When 

reading

--ol-

, remove the item on the hook to avoid damage to the 

load cell. 

Summary of Contents for DR Series

Page 1: ...www scalesearch co uk UGDR E0 01 DR series Hanging Scales technical guide...

Page 2: ......

Page 3: ...Descriptions of keys 3 2 2 Display 3 SECTION 3 OPERATION 5 3 1 General instruction 5 3 2 Basic operation 5 3 2 1 ON OFF 5 3 2 2 Zero the scale 5 3 2 3 Reading lock 5 3 2 4 Overload warning 5 SECTION 4...

Page 4: ......

Page 5: ...tpoint control Power saving mode Remote control included with control distance 20 m One charge can be lasting up to 35 hours Low power indication and auto power off 1 2 SPECIFICATIONS Model DR 30 DR 6...

Page 6: ......

Page 7: ...www scalesearch co uk 1 3 DIMENSION Different with 30kg...

Page 8: ...u can see the conversion of the units when in setting mode use this key to escape setting 2 2 Remote controller key function 30kg without this function 1 TARE 2 ZERO 3 UNIT 4 HOLD 2 3 DISPLAY BATT bat...

Page 9: ...ERATION 3 2 1 Power on and off Please press ON OFF key before you operate this scale and press ON OFF key again after you operate this scale 3 2 2 Zero the scale When there is no item on the scale but...

Page 10: ...automatically switch off to protect the battery 4 The battery should be charged for 12 hours for full capacity 5 Just on the right side of the display these is an LED to indicate the status of batter...

Page 11: ...ey to move the active digit use TARE key to increment a digit after input calibrate mass weight press ZERO key to sure display show LOAD add calibrate mass on hook after Hold indicator on press ZERO k...

Page 12: ...without this function Inc 5 Inc 10 inc 5 F3 a2n Set zero tracking range 30kg without this function 0 5d 0 5d 1d 1d 2d 2d 4d 4d 1d F4 Flt Set filter range 30kg without this function FLT 1 fast FLT 2 F...

Page 13: ...www scalesearch co uk F8 cal Calibrate Uload calibrate weight load complete See detail at SECTION 5...

Page 14: ...ain Err 5 Keyboard Error Keyboard short please check the key wire whether the key have mechanical problem Err 6 A D out of range The values from the A D converter are outside the normal range Remove w...

Reviews: