RWP Weighing Indicator Technical Manual(v1.16)
- 20 -
cal
Linear
Linear calibration
nonlin
Normal calibration
Crpcal
Creep calibration
Dua
ra
For Dual Range Settings
Deci
Decimal point settings
Inc
Div 1
Set the scale first increment
Div 2
Set the scale second increment
Cap
Cap 1
Enter the scale first capacity
Cap 2
Enter the scale second capacity
cal
Linear
Linear calibration
nonlin
Normal calibration
Crpcal
Creep calibration
duai
n
For Dual Interval Settings
Deci
Decimal point settings
Inc
Div 1
Set the scale first increment
Div 2
Set the scale second increment
Cap
Cap 1
Enter the scale first capacity
Cap 2
Enter the scale second capacity
cal
Linear
Linear calibration
nonlin
Normal calibration
Crpcal
Creep calibration
P3 pro
Count
This display will show XXXXX for indicating the internal
counts.
Reset
Factory default settings
gra
Set the local gravity
P4 chk
Mode 1
Normal weighing mode. (check weighing, accumulation)
Mode 2
Animal weighing mode. (scale can lock reading, when
little unstable)
Mode 3
This is a subtraction scale (print out “-“ weight)
Mode 4
Peak Hold mode. (Scale can hold maximum reading)
Summary of Contents for RWP