94
WEB Interface
CP525 cMux User’s Manual Rev. 5.20.12 (3944)
ID: um_tsmux
15mins
Displays the result of the previous 15 minutes counting interval.
Section
“Section” related error counts
Line
“Line” related error counts
Path
“Path” related error counts
At the page bottom is the
Clear Module Statistics
button. Clicking this will flush all error
counters.
The
STM-1/OC-3 Config
page.
The STM-1/OC-3 module provides an optical interface for high speed data communications in
SDH or SONET networks. This page provides access to change the configuration settings of
the module. As shown in figure
the page contains four fields to set operational
parameters. The
Alarms
and
Error counters
fields are identical to those described for the
SFP
Status
sub-page. Editing the configuration settings will alter the SFP configuration file stored
in the CP525, only.
Figure 8.23
The configuration page
for the STM-1/OC-3 SFP module
In the
General
field the main operational parameters are set.