Electronic control system
65
t7
The time the table turns at half speed before stopping, after the last
sensor by-pass t6 has taken place.
t8
The time the table is standing still before turning at half speed to the
bale unloading position, after the table has stopped.
t9
The table raising time before bale unloading.
t10
The time delay before lowering the table.
t11
The time delay after the table is fully lowered.
t12
Not in use.
t14
The maximum interval between the pulses of the film sensor when
wrapping in automatic mode.
> Push to confirm
Setting
Recommended setting
sec and 1/10 sec 1.5 - 2.5
Setting
Recommended setting
sec and 1/10 sec 0.5 - 0.7
Setting
Recommended setting
sec
4 - 6
Setting
Recommended setting
sec and 1/10 sec 0.3 - 0.5
Setting
Recommended setting
sec and 1/10 sec 0.3 - 0.5
Setting
Recommended setting
sec and 1/10 sec 1.0