4
Remote Programming Reference
Modulated Waveforms Control Commands
4-53
The 5251 will return LIN, or LOG depending on the selected spacing setting.
SWEep:MARKer<frequency>(?)
Description
This function programs marker frequency position. Sweep marker can be placed in between the start and
the stop frequencies. The marker pulse is output from the SYNC output connector.
Parameters
Name
Range
Type
Default
Description
<frequency>
10 to
100e6
Numeric
10e3
Programs the marker frequency position in units of
Hz.
Response
The 5251 will return the present marker frequency value. The returned value will be in standard scientific
format (for example: 100mHz would be returned as 100e-3 – positive numbers are unsigned).
Summary of Contents for 5251