background image

-10-

This equipment has been tested and found to comply with the 

limits for a Class B digital device, pursuant to part 15 of the FCC 

Rules. These limits are designed to provide reasonable protection 

against harmful interference in a residential installation. This  

equipment generates, uses and can radiate radio frequency 

energy and, if not installed and used in accordance with the 

instructions, may cause harmful interference to radio commu-

nications. However, there is no guarantee that interference will 

not occur in a particular installation. If this equipment does cause 

harmful interference to radio or television reception, which can 

be determined by turning the equipment off and on, the user is 

encouraged to try to correct the interference by one or more of 

the following measures: 

Reorient or relocate the receiving antenna. 
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from 

that to which the receiver is connected. 
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Industry Canada license exempt RSS 

standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and 
(2) This device must accept any interference, including interfer-

ence that may cause undesired operation of the device. 
Le présent appareil est conforme aux CNR d’Industrie Canada 

applicables aux appareils radio exempts de licence. L’exploitation 

est autorisée aux deux conditions suivantes: 

(1) l’appareil ne doit pas produire de brouillage, et 
(2) l’utilisateur de l’appareil doit accepter tout brouillage  

radioélectrique subi, même si le brouillage est susceptible  

d’en compromettre le fonctionnement. 
Under Industry Canada regulations, this radio transmitter may 

only operate using an antenna of a type and maximum (or lesser) 

gain approved for the transmitter by Industry Canada. To reduce 

potential radio interference to other users, the antenna type and 

its gain should be so chosen that the equivalent isotropically  

radiated power (e.i.r.p.) is not more than that necessary for  

successful communication. 
Conformément à la réglementation d’Industrie Canada, le  

présent émetteur radio peut fonctionner avec une antenne  

d’un type et d’un gain maximal (ou inférieur) approuvé pour 

l’émetteur par Industrie Canada. Dans le but de réduire les risques 

de brouillage radioélectrique à l’intention des autres utilisateurs, il 

faut choisir le type d’antenne et son gain de sorte que la puissance 

isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité 

nécessaire à l’établisse-ment d’une communication satisfaisante.
To comply with FCC and Industry Canada RF radiation exposure 

limits for general population, the antenna(s) used for this trans-

mitter must be installed such that a minimum separation distance 

of 20cm is maintained between the radiator (antenna) and all 

persons at all times and must not be co-located or operating in 

conjunction with any other antenna or transmitter.

CAUTION

Summary of Contents for 0018e-SF4

Page 1: ...tivation Proportional pressure TRV Panel Radiator variable speed 2 variable pressure differential settings Med or High Constant pressure ZV Zone Valve variable speed 2 constant pressure differential settings Med or High Fixed speed ZONE CIRC zoning with circulators infinitely adjustable MIN MAX settings 4 operating modes in 0018eTM Mobile App activation Fixed Speed infinitely adjustable MIN MAX se...

Page 2: ...lité de liquides CAUTION Installations at elevations over 5000 feet must have higher fill pressure of 20 psi minimum to prevent pump cavitation and flashing Premature failure may result Adjust expansion tank pressure to equal fill pressure A larger size expansion tank may be required ATTENTION Des installations à des altitudes de plus de 1600 mètres doivent présenter une pression de remplissage pl...

Page 3: ... system piping The circulator flanges incorporate a nut grabber feature for easier installation 4 Union Model Install the union tailpiece fitting set sold separately best suited for your system piping See union fitting options chart on the back cover Install circulator by attaching pump casing to each union tailpiece fitting Tighten union nut onto circulator threading being careful not to overtigh...

Page 4: ...tage du circulateur sur des chevêtres de mur ou de plancher 5 Filling the system The system must be filled before operating the circulator The bearings are water lubricated and should not be allowed to operate dry Filling the system will result in immediate lubrication of the bearings It is always good practice to flush a new system of foreign matter before startin the circulator WARNING Risk of e...

Page 5: ...ection The 0018e is a double insulated circulator No grounding wire is necessary 7 Start the circulator When purging the system it is recommended to run the circulator at manual full speed operation long enough to remove remaining air from the bearing chamber To do this turn the dial clockwise to the ZONE CIRC MAX position This is especially important when installing the circulator in the off seas...

Page 6: ...018e_UserManual 1 Search for Taco 0018e ECM Circulator mobile app within the App Store or Google Play on your mobile device 2 Download the Taco 0018e ECM Circulator mobile app for free and install it on your mobile device 3 Once complete you are able to start using the app Additional operating instructions can be found on the app itself Turn the selector dial counter clockwise to the Bluetooth set...

Page 7: ...resents full operating range Blue LED min max ZONE CIRC FIXED SPEED MODE 0018e Performance Curves In TRV Panel Radiator Proportional pressure mode the circulator maintains a proportional pressure differential Δp v as heating load increases or decreases Flow will change in relationship to the change in pressure differential Selection options are Medium or High If unsure on proper setting select Med...

Page 8: ...nt supply voltage Verify that the power supply matches the data on the name plate Building does not get warm LED on The circulator performance is too low Increase the suction head Increase speed or P setting 7 Troubleshooting the error codes Listed below are potential diagnostic error codes which will appear on the LED display in case of a malfunction Unlocking Procedure A red light in the LED ind...

Page 9: ... SFL 050T 1 2 NPT SFL 050S 1 2 Sweat SFL 075T 3 4 NPT SFL 075S 3 4 Sweat SFL 100T 1 NPT SFL 100S 1 Sweat SFL 125T 1 1 4 NPT SFL 125S 1 1 4 Sweat SFL 150T 1 1 2 NPT SFL 150S 1 1 2 Sweat SPEED Taco Grundfos Wilo Xylem B G Armstrong Minimum 003 006 Alpha 15 55 Low Compass 1 Medium 007 008 0015 Low 0015 Med UP 15 42 UPS 15 58 Low UPS 15 58 Med Alpha 15 55 Med Star S 21 1 Star S 21 2 NBF 1 2 Astro 230 ...

Page 10: ...nada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement Under Industry Canada regulations this radio transmitter may only operate using...

Page 11: ... 11 NOTES ...

Page 12: ...consequential damages so these limitations or exclusions may not apply to you LIMITED WARRANTY STATEMENT Taco Inc will repair or replace without charge at the company s option any Taco product which is proven defective under normal use within three 3 years from the date code In order to obtain service under this warranty it is the responsibility of the purchaser to promptly notify the local Taco s...

Reviews: