6
The FWCK can control the fl ow to 4 more fresh water stations by means of stop valves.
The fi rst fresh water station runs independently. The secondary fresh water stations
fl own are controlled via stop valves. A fl ow sensor is integrated into every single
station. The FWCK is monitoring the entire fl ow. 4 On and Off limits are set in the
FWCK, at which the individual stations stop valves are switched.
To ensure an equal use of the fresh water stations the FWCK changes the station
switched fi rst when the fl ow reaches 0 L/min.
Important characteristics of the FWCK:
-
Depiction of graphics and texts in a lighted display
-
Simple viewing of the current measurement values
-
Analysis and monitoring of the system by means of statistical graphics,etc.
-
Extensive setting menus with explanations
-
Menu block can be activated to prevent unintentional setting changes
B.2 About the controller
Description of controller
-
Temperature Difference Controller FWCK
-
replacement fuse 2A slow-blow
-
Installation and operating instructions
B.3 Scope of supply
B.4 Disposal and pollutants
The unit conforms to the European RoHS directive 2011/65/EU for the restriction of the
use of certain hazardous substances in electrical and electronic equipment.
Caution
Caution
Caution
The unit must not under any circumstances be disposed of with ordinary
household refuse. Dispose of the unit only at appropriate collection
points or ship it back to the seller or manufacturer.
Every fresh water station has to be equipped with a fl ow limiter to
prevent damage to the VFS.
Every fresh water station has to be confi gured separately.