background image

Tactical Controls Limited

Power Enclosure Assembly Instruction Manual

10.

A projector dimmer controller (Ref: Tactical 150LD).

11.

A dimmer data external cabinet connector. This is made via a DIN 5-way audio socket
connector 240º twist lock bayonet (PREH) type (Ref: RS 453-448).

12.

Dimmer controlled mains internal connection is to be wired via two DIN rail mounted
terminal blocks.

13.

External cable glands:

3 off PG9 (for DC supplies and data).
8 off PG11 for mains and DC supplies.

14.

DC supplies external cabinet connectors are via 2 off Thomas and Betts 9-way chassis
mounted sockets (Ref: RS 484-341). These are wired with key "A" and "B" orientation.
The contacts are 0.75 to 1.5mm2 wire type.

15.

The cabinet dimensions are 700mm high x 700mm wide x 300mm deep. These are to be
exclusive of floor mounting feet, glands, connectors and buttons.

16.

There is provision for wall mounting via 4 off 8mm inverted key hole at the back of the
cabinet and floor free standing on 4 rubber feet.

17.

The paint finish is colour Green RAL 6031 Matt.

18.

The casing and door are earthed.

19.

Internal wiring are made to drawings 46 486 649-197.

20.

The  following  labels  are  located  at  suitable  locations  and  without  any  language
dependant text:-

High voltage symbol inc voltage range "215 - 240V" and frequency "50Hz".
Earth Point symbol

21.

Suitable vents are provided to enable the vacuum exhaust to operate.

22.

Two off, door mounted low profile neon lamps (green) are fitted to indicate the status of
each of the two poles of mains supply after the circuit breakers.

23.

One  off,  door  mounted  low  profile  filament  lamp (red)  is  fitted  to  indicate  any  mirror
fault.

24.

One off, 20 meters 2 core cable connected to a remote stop button is fitted.

25.

One off, door mounted green push button for the start of the power cabinet.

26.

One  off,  15 meters  3  core mains cable ended with Schuko  mains  plug is  connected  to
both poles.

27.

One off, Schuko mains socket is fitted on the right gland plate for test equipment.

pea\im

Page 4

16 March 1998

Issue 4.0

Summary of Contents for PEA

Page 1: ...ent contains proprietary information which is protected by copyright All rights reserved This document or parts thereof may not be reproduced in any form without written permission of the publishers The information in this document is subject to change without notice and should not be construed as a commitment by Tactical Controls Limited Tactical Controls Limited shall not be liable for errors co...

Page 2: ...with its controller and Inverter and Mirror protection circuitry Mains distribution Elapsed time counter mains switch and the mains circuit breakers Block diagram ALL DIMENSIONS ARE IN MM GENERAL TOLERANCE X 0 5 X X 0 05 All Rights Reserved C Filename Size Drawing No Title Tactical Controls Limited Rev Description Iss Chk Auth Date A3 DIMMER CONTROL PEA BLOCK DIAGRAM PEA DWG BLOCK BLOCK DC SUPPLIE...

Page 3: ...nts Two poles of distributed mains 2 5 or 4 mm2 type with a minimum of Pole 1 8 live terminals points 8 neutral terminals points Pole 2 8 live terminals points 8 neutral terminals points Common earth consisting of 16 earth terminals points Four terminals points for dimmer output Two 10 amp Circuit breakers Twelve terminals points for mirror position sensor input limit switch input and mirror prote...

Page 4: ...hole at the back of the cabinet and floor free standing on 4 rubber feet 17 The paint finish is colour Green RAL 6031 Matt 18 The casing and door are earthed 19 Internal wiring are made to drawings 46 486 649 197 20 The following labels are located at suitable locations and without any language dependant text High voltage symbol inc voltage range 215 240V and frequency 50Hz Earth Point symbol 21 S...

Page 5: ...N 1997 RAL6031 PAINT FINISH 300 0 700 0 1 KEY OPERATED DOOR LOCK 2 DOOR HINGES 700 0 20 OFF 3X25MM AIR VENT ON BOTH SIDES OF CABINET ON A 240X120 GLAND PLATE STEEL CABINET TO BE BOTH WALL MOUNTED THROUGH 4 X M8 INVERTED KEYHOLE AT FOUR CORNERS AND FREE STANDING ON 4 RUBBER FEET 8 PG11 CABLE GLANDS D SHAPED DOOR HANDLE ELAPSED TIME COUNTER 20 0 150 0 M5X15 STUD ON BOTH SIDES OF CABINET 55 0 590 0 5...

Page 6: ... mains cable with a Schuko plug fitted 2 Mains distribution to Compressor L N and E on TB1 1 5 and 22 Mains distribution to Instructors station L N and E on TB1 11 15 and 23 Mains distribution to Firing station L N and E on TB1 12 16 and 24 3 DC power supplies 12V 5V 5V and 12 sense Panel mounted socket SK1 12V 12V 24V and earth Panel mounted socket SK2 24V for comms control Terminal 2 and 7 on PS...

Page 7: ...isabled The fault lamp is lit indicating the presence of mirror fault Provided the fault no longer exists the latching circuit can be cleared by either pressing the Reset button or turning off the power Please refer to the following diagram for further details ULTRA SONIC TRANSDUCER LATCHING RELAY FAULT ALL DIMENSIONS ARE IN MM GENERAL TOLERANCE X 0 5 X X 0 05 2 LAMP L3 2 RESET BUTTON PB1 1 LIMIT ...

Page 8: ...4 0 2 2 0 C a b in e t E a rth TB 1 2 0 B o o tla c e C a b in e t M 5 rin g G N Y L A W G 1 6 2 1 P S 1 E a rth TB 1 2 1 B o o tla c e P S 1 E M 4 fo rk G N Y L A W G 1 6 2 1 M o to r E a rth TB 1 2 1 B o o tla c e M 1 E M 4 rin g G N Y L A W G 1 6 2 2 S K 2 E a rth TB 1 2 2 B o o tla c e S K 2 9 C rim p G N Y L 2 4 0 2 2 2 F L 1 E a rth TB 1 2 2 B o o tla c e F L 1 E B o o tla c e G N Y L A W G ...

Page 9: ... 1 L b la d e TB 2 4 L b la d e B ro w n A W G 1 6 5 8 S w it c h 1 L 1 t o TB 2 TB 2 1 L b la d e S W 1 1 M 4 fo rk B ro w n A W G 1 6 5 8 S w it c h 1 L 2 t o TB 2 TB 2 4 L b la d e S W 1 3 M 4 fo rk B ro w n A W G 1 6 5 9 S w it c h 1 N 1 t o TB 2 TB 2 2 L b la d e TB 2 5 L b la d e B lu e A W G 1 6 5 9 TB 2 N 1 t o N 2 TB 2 5 L b la d e S W 1 5 M 4 fo rk B lu e A W G 1 6 5 9 S w it c h 1 N 2 t...

Page 10: ...24 21 14 11 22 A2 A1 12 22 A2 A1 12 1 5 3 N7 2 6 4 N8 1 2 7 5 3 4 6 8 A1 A2 0 240 0 24 4 3 1 2 3 E N L 5 3 1 E N L 5 4 3 L N E 20 21 E 14 L 16 N STF SD V E 2 5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 0V 1 9 1 2 3 4 5 6 7 8 V V V V S S S S V V V V 5 5 5 0V 0V 0V 2 3 4 5 6 7 8 9 10 12V 5V 0V 0V 11 12 13 0V N E 6 7 N 9 10 11 12 2 1 L 5 STROBE CLOCK 0V DATA OP 8 4 3 X X X TO CABINET EARTH STUD DOOR EAR...

Page 11: ... Reliability MTBF of not less than 1000 hours Supply 215 to 240Vrms 5 50Hz 1 Temperature 0 to 50 ºC operating 20 to 65 ºC storage Dimensions 700mm H x 700mm W x 300mm D Mounting positions Wall mounted on fixing centres 590 x 600mm or free floor standing on 4 rubber feet Weight 65Kg max References Critical Item Design Specification CIDS for the Power Cabinet PCAB HWCI of the Power and Air PAIR HWCI...

Page 12: ...ion Ordering code PEA You are welcome to order the unit by code or description PEA Power Enclosure Assembly Supplier information Tactical Controls Limited Unit 4 Marlborough Road Lancing West Sussex BN15 8TR England Tel 01903 750800 Fax 01903 750678 pea im Page 12 16 March 1998 Issue 4 0 ...

Reviews: