4-16
Software Installation Procedure
Coral FlexiCom 6000 Installation Manual
Hot S
tandb
y Con
figu
ration
Mod
e
s
4
OTHER 32GC
EXISTS
Yes/No
Read-Only
Displays whether the 32GC card is installed on the
other system side.
CONTROL SIDE
0-Right
1-Left
Read-Only
Shows which side is currently the Active (Control)
side of the redundant system.
Main Peripheral
Switch Connected
Yes/No
Read-Only
Shows whether the peripheral cards are connected
to this side of the redundant system.
Last Swap
Date & Time
Read-Only
Displays the Date and Time of the last system
swap between the Active and Standby side.
Auto Hot Swap
Yes
/
No
Default: No
Defines whether or not the right and left sides
should be automatically swapped by the system.
Enter Yes for Auto Swap.
Number of Days
between Hot
Swaps
1
to
255
;
Default: 1
Defines the number of days between the swaps.
Set Auto Swap
Time
00:00-
23:59
;
Default: 1:00
Defines the time to perform the automatic hot
swaps.
Auto Maintenance
Termination
Yes
/
No
Default: No
If the Standby side was manually switched to
Maintenance mode, setting this parameter to Yes
safeguards the system by automatically reverting
the system back to Standby mode after a
predetermined number of hours.
Auto Maintenance
Termination Time
1
to
255
Hours;
Default: 24
Defines the time period before the system
automatically returns the Maintenance side to
Standby mode.
Status
0
-Active
1
-Standby
3
-Maintenance
Choose the control status for this side of the
system.
If Standby (1) or Maintenance (3) is chosen, the
other side must be in Active mode (0).
Other Control
Status
0
-Active
1
-Standby
3
-Maintenance
No_Comm
Choose the control status for the other side of the
system. If Standby (1) or Maintenance (3) is
chosen, the other side must be in Active mode (0).
NO_COMM indicates that this is currently not a
redundant system.
Update Status
Yes/No
Choose Yes to change the system status as
chosen in the previous parameters.
Choose No to retract.
Parameter Name
Range
Description