7-8
Power Supplies
Coral FlexiCom 6000 Installation Manual
PPS
Peripheral Power Su
pply Unit
7
PPS (Peripheral Power Supply)
Coral systems:............................................. FlexiCom 400, 5000, 6000
Input:........................................................... -42 to -58VDC, 20A Max.
DC Outputs: ................................................+5VDC Nom. Regulated 15.0A Max.
–5VDC Nom. Regulated 3.0A Max.
+12VDC Nom. Regulated 8.0A Max.
–12VDC Nom. Regulated 0.15A Max.
–48VDC Unregulated 8.0A Max.
Indicators: ...................................................Power ON
Output Voltages Test Jacks
Fuses: ..........................................................
Input (DC-DC Converter) .......F1: 8A
Input (Peripheral) ....................F2: 15A
Controls and Adjustments: .........................ON/OFF Power Switch
+5V Adjust
+12V Adjust
–5V Adjust
6.
Blown main or circuit fuse/breaker in the building electrical panel.
Indicators: ...................................................Power ON/OFF (green)
ALARM (red)
(Protected by a fuse on the rear panel of the cage)
Weight:................................................................. 1.4 kg
...................................................................................................
6
Specifications