6-20
Cabinet Descriptions
Coral FlexiCom 6000 Installation Manual
Cabinet Descrip
tion
s
6
Figure 6-17
H624
Crossover Cable
The I/O connection is made via LDF or UDF as follows:
LDF panel (Catalog Number 7244-9043100) is used for PUGW, UGW-E,
PUGW, MAP, CLA and IPG cards.
UDF panel (Catalog Number 7244-9044100) is used for
30T/30TM/T1/PRI-23/PRI-30 (layout UDT or 2DT) cards.
The LDF (LAN Data Filter) and the UDF (Universal Digital trunk Filter)
incorporate improved RFI immunity. These filters enable the Coral and all
relevant peripheral interface circuits to be fully protected against
radio-frequency interference (RFI) and meet or exceed all requirements and
specifications of telecommunications and electrical safety authorities
world-wide.
The Coral FlexiCom 6000 cabinet is supplied with:
1 (one) LDF panel (four RJ-45 connectors for UGW, UGW-E, PUGW and
IPG cards)
4 (four) H624 crossover cables
Additional H624 cables and three LDF/UDF panels may be field installed as required.
For further information on:
How to make the connection, see
Chapter 2
in this manual.
Pinout connection, see
Chapter 5.9
of the
Coral
FlexiCom 300, 400, 5000Installation Procedure and Hardware Reference
Manual.
It is imperative that a crossover cable (Catalog Number 7244-8000624) be used
to make this connection. If an ordinary cable is used the cards will not be
integrated into the system.
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
RJ-45
RJ-45
H 624 Cable
Cat. No. 72448000624