3-10
Initial Power-Up Tests
Coral FlexiCom 6000 Installation Manual
Co
mm
on
C
o
nt
ro
l T
est
3
Attach XMM
6.
A 4/8XMM card is required when installing CLA-ATS card in the system or
when the system requires more RAM memory. When a 4/8XMM card is
required, attach the XMM card as described in
.
Insert 32GC
7.
Reinsert the 32GC card fully into its slot by following steps
.
Repeat Steps
to
for the second 32GC located on the Control Shelf.
8.
Verify that the slot in the control cage chassis matches the card to be installed.
Card types are marked under and above each of the card slots. On the top and
bottom of each card slot there are coded keys to match corresponding coded
keys on the top and bottom of each card so that an incorrect card may not be
inserted.
9.
Verify that the card is oriented correctly:
For the right side of the control shelf, insert cards up-right.
For the left side of the control shelf, insert cards upside down.
10.
Grasp the injector/ejector levers on the top and bottom of the card’s front
panel, with one hand on the top lever and the other hand on the bottom lever.
11.
Align the edges of the circuit card with the card edge guides in the card cage.
12.
Gently slide the card straight into the card slot. Resistance is felt as the
multi-pin connectors on the circuit card meet mating connectors on the
backplane and engage.
13.
Push the injector/ejector levers inward until the front panel of the card is flush
with the front frame of the card cage. Do not force the circuit card into the
slot. If increased resistance is encountered, remove the circuit card and
examine the connectors for bent pins or interfering debris.
14.
Verify that the card is sitting properly in its slot.
15.
Secure the card to the control cage chassis, by fastening the screws in the
appropriate holes located above the upper lever and below the lower lever.
Verify 32GC Dip Switch
Position
16.
Verify the positions of the DIP switches on the front panel of the 32GC card.
They all should be pointing away from the numbers.
Attach SAU
17.
The SAU device and its corresponding CFD memory card are shipped in their
own Coral Software box. Two separate Coral Software boxes are provided for
HSB systems, one for the right side of the Control Shelf, and one for the left
side.