4-2
Coral IPx 500 Installation Manual
Generic Feat
ur
e Soft
w
ar
e Upg
rade
4
0
0
Use FMprog version 5.xx and above. Otherwise, the Coral will not initialize.
The upgrade of the generic feature software involves three main steps:
1.
Installing the FMprog-Utility (version 5.xx and later)
2.
Extracting the new Coral generic feature software file into the PC hard disk
3.
Programming the new generic software upgrade to the IMC8 card
The FMprog-utility can be used to backup the Coral software into PCMCIA cards. The
backup file is in a binary format and includes all the software components of the
specific Coral system from which it was copied, including the Coral generic software
version, the switch authorization, and the database. Copies should be made and
maintained at every customer site. Each site has its unique set of software
configuration, including its main software version, switch authorization and database,
as well as its specific Software Authorization Unit (SAU) information. Copies of all
system files exist and are available for use via the FMprog-Utility, if they are needed.
Use the FMprog-Utility to:
Manage your new database versions
Load the Coral generic version, authorization and database information on to
flash memory cards
Extract version, authorization, and database information from source files
Removing the IMC8 Card
To remove the IMC8 card from the Coral IPx 500 system:
1.
Press the Reset button on the MCP-IPx card.
2.
Press the Release button on the MCP-IPx card to remove the IMC8 card.
2
Upgrading Using the FMprog PC-Utility
Before each installation or removal of an IMC8 card from the Coral IPx 500, press the
RESET button on the MCP-IPx card.
Do not remove the IMC8 card from the MCP-IPx when “P” is illuminated. The MCP-IPx
numeric status display indicates various operating and error states of the Coral IPx 500
system. A “P” appears during software installation or backup.
Summary of Contents for Coral IPx 500
Page 22: ......
Page 26: ......
Page 28: ......
Page 42: ......
Page 58: ...2 16 Coral IPx 500 Installation Manual Site Inspection 2 NOTES...
Page 120: ......
Page 126: ...3 6 Coral IPx 500 Installation Manual Power Supply Test 3 NOTES...
Page 152: ...3 32 Coral IPx 500 Installation Manual Installation Wrap up 3 NOTES...
Page 154: ......
Page 170: ......
Page 184: ...5 14 Coral IPx 500 Installation Manual Protection Devices 5 NOTES...
Page 188: ...5 18 Coral IPx 500 Installation Manual Power Fail PF Transfer Circuits 5 NOTES...
Page 204: ...5 34 Coral IPx 500 Installation Manual MDFipx Units Supplied by the Manufacturer 5 NOTES...
Page 256: ......
Page 288: ...6 32 Coral IPx 500 Installation Manual Coral IPx 500M Main Cage Description 6 NOTES...
Page 296: ...6 40 Coral IPx 500 Installation Manual Coral IPx 500X Expansion Cage Description 6 NOTES...
Page 316: ......
Page 332: ...7 16 Coral IPx 500 Installation Manual PS500 DC Power Supply Unit 7 NOTES...
Page 350: ...7 34 Coral IPx 500 Installation Manual PS500 AC Power Supply Unit 7 NOTES...
Page 376: ......
Page 380: ...8 4 Coral IPx 500 Installation Manual Control Cards 8 NOTES...
Page 404: ...8 28 Coral IPx 500 Installation Manual IMC8 Card Flash Erasable Software Memory Unit 8 NOTES...
Page 412: ...8 36 Coral IPx 500 Installation Manual DBX Card Database Expansion Memory Unit 8 NOTES...
Page 426: ...8 50 Coral IPx 500 Installation Manual CLA Card CoraLINK Adapter 8 NOTES...
Page 428: ......
Page 432: ...9 4 Coral IPx 500 Installation Manual Shared Service Circuitry Installation 9 NOTES...
Page 460: ...9 32 Coral IPx 500 Installation Manual Three Way Conference Conference Circuitry 9 NOTES...
Page 490: ...9 62 Coral IPx 500 Installation Manual KB1 KB2 KB3 RS 232E Data Serial Port 9 NOTES...
Page 498: ...9 70 Coral IPx 500 Installation Manual Music Background and Music On Hold M1 M2 9 NOTES...
Page 518: ...9 90 Coral IPx 500 Installation Manual Relay Contacts RLY1 RLY2 RLY3 9 NOTES...
Page 520: ......
Page 526: ...10 6 Coral IPx 500 Installation Manual Peripheral Card Installation 10 NOTES...
Page 543: ......