Emerald ICE Quick Installation Guide
Page 2-19
Electrical Specifications
AC Power Source:
Dedicated 117/ 15%, 47-63Hz single phase
Power consumption:
1.5A maximum @ 120vac (180 watts)
Power Supply Fuse:
AC enter: 2A 250v
DC output: 1A 125v
Idle Channel Noise:
-74 dB
Cross Talk Attenuation:
75 dB (@ 1kHz)
Ringing Sensitivity:
40v RMS 25 Hz
Ringer Equivalence Number:
1.5
CO Line Signaling:
DTMF amplitude (-5 dB,-7 dB) +- 2 dB, @ approx. 2 Vpp
Pulse Dialing ratio 60/40 @ 10 PPS
Music source / Background Music:
0 dBm at 600 ohm enter impedance; 1/8th inch phono
jack
Contact rating (Option Module LBC):
1A @ 30VDC; 0.5A @ 90VAC 30Hz; 1/8th inch phono
jack
External Page Port:
0 dBm at 600 ohms; 1/8th inch phono jack
Environmental Data
Operating Temperature:
0
o
to 40
o
C, 32
o
to 95
o
F
Recommended Operating Temperature:
70
o
to 78
o
F
Storage Temperature:
32
o
to 104
o
F
Operating Relative Humidity:
5% to 90% (non-condensing)
Heat Dissipation (BTU):
300
Wiring Data
Deluxe/Standard Model Telephones (Distance measures in linear feet of cable from KSU
to phone):
26 AWG - 255m (850 ft.)
24 AWG - 425m (1416 ft.)
22 AWG - 700m (1983 ft.)
Standard Single Line Telephone (Distance measures in linear feet of cable from KSU to
SLT):
26 AWG - 195m (650 ft.)
24 AWG - 340m (1133 ft.)
22 AWG - 476m (1586 ft.)
Summary of Contents for EMERALD ICE
Page 1: ...Emerald ICE Digital Key Telephone System TM Quick Installation Guide...
Page 6: ...vi NOTES...
Page 7: ...Section 1 Introduction...
Page 8: ...NOTES...
Page 12: ...NOTES...
Page 13: ...Section 2 System Design...
Page 14: ...NOTES...
Page 40: ...NOTES...
Page 41: ...Section 3 Installation...
Page 42: ...NOTES...
Page 54: ...Section 3 Installation Page 3 12...
Page 55: ...Emerald ICE Quick Installation Guide Page 3 13...
Page 57: ...Section 4 Basic Programming...
Page 58: ...NOTES...
Page 68: ...NOTES...
Page 69: ...Section 5 Programming Quick Reference Charts...
Page 70: ...NOTES...
Page 137: ......