PCP-1500/2000
A
/
2000/
5000 Series
Rev 3
2023/01/16
18/52
Copyright © 2023 by TAEHA CORP. All Rights Reserved
4.3
Check the shot amount
1) Please attach the needle you want to use.
2) Set it to steady mode and dispense continuously until the liquid is discharged from the
needle.
3) Repeat shot on and off. If there is liquid at the end of the needle, correct the suck back
time / suck back speed to an appropriate value.
(Excessive suck-back setting may cause backflow of mixed liquid into the pump and cause
malfunction.)
4) Set the appropriate shot time by setting the time mode, and check whether or not the
dispensing is performed on the prepared measuring cup.
Pro-Pump is linearly proportional to time and velocity.
Calculated by the proportional method, you can dispense it like you want.
5) If the discharge amount is more than 3% difference than usual, you may suspect the wear
of Pro Pump. In this case, replace the stator.