TAG Heuer Timing
Page 16 / 44
5.3. Speed
Selectable Speed unit of measurement is m/s, Km/h, Miles/h and Knots. Four different speed
measurements can be configured between the 4 inputs.
Ex: for Speed 1 between inputs 2 and 3 at a distance of 10 meters:
Start
Press 2, and validate
◄┘
Stop
Press3, and validate
◄┘
Distance
To input the distance between the photocells in millimetres:
Press 10’000 and validate
◄┘
.
Use
to correct any input error. Re-enter the input correctly then validate
◄┘
When finished (for instance, if only one speed trap is to be configured) simply press
F
.
PLEASE NOTE
Speed measurements are possible in all the timing modes above, with the exception
of PARALLEL DIFFERENTIAL.
5.4. Printer
Printer may be ON or OFF.
To guarantee the best printing autonomy, the speed of the printer is electronically controlled based on
the voltage of the batteries.
If the voltage decreases, the printing speed will slow down.
If the batteries fall below a certain voltage threshold, the printer will automatically stop. The running
Time of Day on the LCD will flash.
To restore the printer, connect an external power supply and then turn the printer ON again from the
menu
F
.
If an external power supply is connected when you turn ON the CP540, the printer will be
automatically ON.
5.5. Download
- To PC: downloads all of the times memorized in one run or in all runs through the RS232 port.
- To Printer: reprints all times memorized in one run or in all runs.
Be sure your batteries are fresh (if not connected to the external power supply) and that there is
adequate paper, especially if you will be printing many times.
Press
to stop the printing at any time.
- To Chrono RS232: to download the time from a run from a Chronoprinter to another one. It is
important to set correctly the Input (see chapter 5.2.4)