background image

8

1. open the osD menu

to open the tagarno on screen display menu, press and hold the 
center button for approximately 5 seconds.

2. Choose lens 

set the current close-up lens by using the left/right arrows on the 
control boX XKeY. on a tagarno full hd system, the choice 
naturally is between lens +3, +4, +5 or +10. lens +4 is factory default. 
continue using the down arrow.

3. Choose monitor width

press the center button to set up the width of the monitor. You need 
to measure the horizontal width of the monitor panel on your monitor, 
select one digit at a time by using the left/right arrows and adjust the 
digits with the up/down arrows. switch between millimeters and inches 
via the up/down buttons. monitor 22” fhd is factory default. to store 
change in settings press the center button.

4. Set start magnification

Select which magnification level you need your FHD system to use as 

start up level. press the center button and select one digit at a time in 
the bottom of the page, by using the left/right arrows and adjust the 
digits with the up/down arrows. by pressing the center button one 
more time, you have selected the values chosen. press the down arrow 
to choose format.

when turning on your full hd system, you are informed of the 
given units, serial number (sn), version and resolution.

On scReen DisplaY (OsD)

OpeRaTiOn (2/2)

5. Choose format 

You have the option to switch between different video formats, 1080p 
60fps being the highest quality. select the required format by pressing 
the center button, and use arrow keys left/right to select between 6 
different formats. 

6. Select OSD presets

You need to choose between respectively alwaYs on, off or 
timeout using the left/right arrows in order to have the osd menu 
displayed continuously, never or for 3 seconds at the time.  
continue by pressing the down arrow.

7. Color boost

the osd menu gives you the possibility to choose between two color 
settings; color boost on or off, by using the left/right arrows. which 
setting chosen, is a matter of individual preferences and the object 
projected on screen. continue by pressing the down arrow.

8. Flip picture

in the menu you have the possibility to rotate the screen image 180 
degrees, or choose the standard view by using the left/right arrows. 
choose between the two views by pressing the left/right buttons. 
continue by pressing the down arrow. press the down button one time 
to mark the save and exit option. 

9. save presets

to save your presets and exit the menu, press the center button and 
thereby return to the image displayed on the monitor, using your 
recently saved presets. 

if you have changed the various formats, your full hd system needs 
to be restarted. this will be indicated in the bottom if needed.

Summary of Contents for FHD ZAP

Page 1: ...ing 2 5 You have received 3 6 Assembling and connecting 4 7 Operation 7 8 Technical specifications 9 9 system requirements 11 10 maintenance 12 11 warranty 12 12 ergonomical recommendations 12 13 DECLARATION OF CONFORMITY 13 version 1 1 2 2017 10 30 manual TAGARNO FHD zap ...

Page 2: ...ARNO 14 Always turn off the system before unplugging when possible WARNINGS Read all safety information before you use the product Please pay attention when you see the warning label on the product The product is a digital magnifying system consisting of a camera unit PCBs mechanical parts and a power supply The product is intended for marketing worldwide and is designed for manual visual inspecti...

Page 3: ...3 Manual Camera Head Power supply Handles 5 You have received XKEY Control box options Angle bracket ...

Page 4: ...4 Mount the handles on the vesa bracket Connect the power supply to the microscope 6 Assembling and connecting Assembling and connecting 1 3 Connect HDMI cable from the microscope to a monitor ...

Page 5: ...nnect USB 3 0 cable from the microscope to a PC WARNING Do not connect the HDMI cable to a PC HDMI cable Assembling and connecting 2 3 Connect grounding cable to grounding point to ensure ESD of the microscope ...

Page 6: ...6 Connect the microscope to the XKEY Control box Detach Vesa mount and handles Mount the angle bracket to the microscope Several options Assembling and connecting OPTIONS 3 3 ...

Page 7: ...3 Keep holding the center button down for 25 seconds 4 Release the center button and turn the power off 5 Turn the power back on and the microscope is set to factory setting 1080P60 Turn off on Laser ON OFF WARNING Laser rediation when turned on Zoom in Zoom out Push both plus and minus to change from auto focus to manual focus You can now adjust the focus manually by using the plus minus buttons ...

Page 8: ...l number SN version and resolution On Screen Display OSD Operation 2 2 5 Choose format You have the option to switch between different video formats 1080p 60fps being the highest quality Select the required format by pressing the center button and use arrow keys left right to select between 6 different formats 6 Select OSD presets You need to choose between respectively ALWAYS ON OFF or TIMEOUT us...

Page 9: ...D 720p 1280x720p at 59 94 50Hz Camera zoom 30x optical Autofocus Yes Power consumption 7 4 W Standby consumption 0 5W Storage 5 60ºC 23 140ºF 20 90 RH Operation 5 40ºC 41 104ºF 20 80 RH Work height Min 95mm 3 74 Max 360mm 14 17 Work depth Adjustable Auto Monitor Detect No Plug connection HDMI USB 3 0 ESD fixed cables Technical specifications 1 2 d d h ...

Page 10: ...r pointer on off Color boost Lens Dimensions 58 mm 2 3 Included lens 4 Lens Lens to object distance Magnification on 22 monitor 3 333mm 13 22 1 2x 36 0x 4 250mm 9 84 1 6x 48 0x 5 200mm 7 87 2 0x 60 0x Recommended monitor format Panel format 16 9 Widescreen How to link HDMI input Response time 2 ms Signal format FHD 1920x1080 Accessories XKEY Control Box Light Kit HD 22 and 24 widescreen monitor An...

Page 11: ...n 1920x1080 recommended FULL HD 1080p 29 97 25Hz anD HD 720p 59 94 50 30 25Hz OS Desktop Laptop Windows 7 8 or 10 with DirectX 11 Memory 4GB CPU Intel Core Dual 3 0GHz or i3 2 4GHz 3rd generation named 3xxx Intel Core i3 3 2GHz 3rd generation named 3xxx Hard Disc Space 1GB required SSD type recommended Connections USB 3 0 xHCI host controller Intel chipset recommended Integrated Graphics Intel HD ...

Page 12: ...be as follows TAGARNO warrants that the product will correspond with the specification at the time of delivery and will be free from defects in material and workmanship for a period of 24 months 2 years from date of invoice from Supplier This warranty shall cover a The replacement of defective parts b All labour costs to exchange defective parts in product c Complete functions test of product befo...

Page 13: ...ve consisting of a camera unit and a 12V power supply is in compliance with the following European directive EMC DIRECTIVE 2014 30 EU By conforming to the following harmonised standards EN 61010 1 2010 EN 61326 1 2013 The declaration is issued by MANUFACTURER TAGARNO A S TAGARNO A S Sandøvej 4 8700 Horsens Denmark 45 76251111 mail tagarno com www tagarno com TAGARNO FHD ZAP Type no 690600 13 DECLA...

Reviews: