XT-1/XT Mini Manual
13-111 05, 2015-08-14
Page 18 of 32
Relay
The relay output can be used to control a barrier, gate, or other object. The relay
can either be activated when any tag has been read or when an accepted tag has
been read. A tag is considered accepted when it is listed in the built-in access
controller's database. The active time can be configured.
Connections
RELAY:COM Common
RELAY:NO
Normally Open
RELAY:NC
Normally Closed
Switching current
Max 2 A
Switch voltage
Max 60 VDC / 30 VAC
Switching capacity:
Max 60 W / 62,5 VA
Max cable length
100 m
Wire size
0.5 mm
2
(AWG 20)
Table 12 Output connection overview
Relay settings are available under Settings…/Interfaces…/Relay in the web interface.
USB
The reader has a USB connector that is used for service and maintenance.
Connections
USB
USB connector
Type B Jack
Speed
12 Mbps ("Full Speed")
MicroSD Memory Card Slot
The reader is equipped with a microSD memory card slot for additional storage.
Connections
MICROSD
The microSD card is needed to use the built-in access controller and logging functionality. Information
about the currently inserted microSD card can be found under Settings…/Interfaces…/MicroSD in the web
interface. On this page it is also possible to format the microSD card.
Tamper Switch (XT Mini only)
The XT Mini reader has a tamper switch that can be connected to an external alarm loop. The circuit is
broken when the lid is opened.
Connections
TMP:TMP A
TMP:TMP B
Figure 17 Inactive relay