6
Tahoe 8216 / Tahoe 8116 Remote Power Management System
Configuration and Management
Th
e remote Power Management System is accessible in many ways either locally or remotely.
Th
e
LCD display and build-in keyboard give direct control over the outlets and basic settings.
Th
e simple
graphical web-based interface makes usage of the device simple and intuitive.
Th
e command line
interface, accessible either remotely via telnet or an encrypted SSH connection or locally through
a serial console, is directed toward more advanced users and gives full control over the device.
Th
e
optional GSM access enables the user to manage the device with short text messages even when
network connection is unavailable.
LCD Menu
Th
e LCD display shows the current state of the device and the build-in keyboard allows the user to
change the state of outlets and gives quick access to basic settings.
Th
e default LCD screen displays
the main unit’s state:
Tahoe 1 2 3 . .
231V 6 7 . 9 10
Th
e displayed numbers indicate enabled outlets while a dot means that the corresponding outlet
is disabled. In the bottom-le
ft
corner of the display the total unit power consumption, current and
voltage are shown sequentially.
Using up and down arrows extension units (if present) may be selected, e.g:
Unit2 1 . 3 4 5
700W . 7 8 9 .
Press the Enter key while the unit state screen is shown to enter the corresponding unit settings.
Th
en use the up/down keys to navigate through the unit menu. For the main unit beside the outlets
state an IP address and a network mask may be set:
IP address
10.0.0.1
Netmask
255.0.0.0