1. Product introduction

-1-

TC-U9AF-CO/Z

ZigBee Carbon Monoxide Gas Detector Installation Instructions

2.Specification

         TC-U9AF-CO/Z is very sensitive to detect the carbon monoxide concentrations. When the gas concentration to achieve a certain 
      standard. The detector will sound and light alarm. And transmit the alarm signal to the alarm center at the same time. This detector,
      with voice broadcast, ZigBee report, temperature mutation alarm, LCD display concentration and other functions, and you can 
      touch the button to set the alarm concentration.
          Its stability, long lifespan, low consumption, wall-mounted installation, elegant in design,360 degree full detection. Easy installation,
      safe and reliable. Commonly used in household residential, real estate and villas, hotels, apartments some of existence of combustible 
      locations.

3.Function Description

          1. LCD display concentration: 0PPM is displayed when CO concentration is less than 30PPM.

          2. By touching the button to set the CO alarm concentration, alarm temperature and alarm humidity: Open the display, trigger 

       the button again to the relevant function.

          3. Sudden temperature alarm: normal standby, when detecting that room temperature continuously changes more than 3 

℃, 

    

it will trigger the detector alarm.

          4. Alarm LCD screen after 30s no operation, automatically shut down.

4.Network Settings

          1. Adjust the gateway to the access mode.

          2. Press the key KEY3 briefly, the detector indicator light will flash, when the network is successful, the indicator light will be on 

      for 2 seconds;

          3. If network can not be normal, long press on the code key for 10 seconds, the indicator light will be on for 2 seconds , then 

      release the key and press the code key again.

5.Key Function Description 

Parameter

Working Voltage

Index

DC6V(3pcsCR2450 battery)

Monitor current:

20uA

Alarm current: 

180mA@max

Carbon monoxide( CO)

150ppm(default)

50

(default)

0%RH(default off)

0~999ppm

0~60

30%RH~100%RH

ZigbeeIEEE802.15.4

2.4GHZ

{ 50,75,100,150,200,300}ppm options

{30,35,40,45,50,55,60}

 options

{0,40,45,50,55,60,65,70,75,80,85,

90}%RH options

Working Current

Test Gas

Alarm Concentration

Alarm Temperature

Alarm Humidity

Concentration Display Range

Temperature Display Range

Humidity Display Range

Network Protocol

Wireless Emitting Frequency

Working Environment

Remarks

temperature:- 10

~50

humidity:15%-95%RH 
(No condensation)

KEY2

KEY1

KEY3

G A S

 

L E A K A G E

p p m

10

0

60

G A S

 

L E A K A G E

p p m

10

0

60

%RH

{0(OFF),40,45,50,55,60,
65,70, 75,80,85,90}

Remarks

The code key

Function

Operation Status

Press once or release 
for one second

Step 1: Press and hold 
for 3 seconds

Step 2: Press and hold 
for 3 seconds

Step 3: Press and hold 
for 3 seconds

Step 4: Press and hold 
for 3 seconds

 long press 5 seconds
  at the meantime 

Manually test alarm

Set the alarm 
concentration

Set the alarm 
temperature

Set the alarm 
humidity

Settings saved 
successfully

The system is 
about to reset

ZigBee only

Parameter settings

{50,75,100,150,
  200,300}

{ 30,35,40,45,
  50,55,60}

KEY3(Key on the left 
 side of the hole)

Voice prompt "It is about to 
proceed  alarm test, do not panic"

You must have this action to 
save the settings.

Key

KEY1(Down key)

KEY1+KEY2

Increase: Release KEY1 once
Reduce: Release KEY2 once

Enroll/Delete

Note:  

① 

Under standby mode, long press KEY1 or KEY2 and light display;

           

② 

After entering the menu, no operation for 15 seconds, which will exit the menu setting.