LED and Voice Message

0.3~1.0m

LCD backlight

Voice broadcast

LCD display "E00"

LCD display "E01"

The red LED flashes

The blue LED flashes

Often off

Power-on

Alarm

Fault

Test

Power-on

Power-on

Alarm

Enroll/Delete

A key is triggered, or the alarm is automatically turned on.

Welcome to use the carbon monoxide gas detector.

Check the carbon monoxide leak, please review.

System self-test do not pass!

It is about to proceed alarm test,do not panic 

The product is not calibrated

Sensor failure

7.Installation

        1. Select the appropriate installation location:
        Because the proportion of CO is lighter than air, the installation location 
        should be 0.3-1.0 meters below the ceiling.
        2. Installation:
        Install the product on the wall with the accessory screws (or on the desktop).

   

Note: Do not install the alarm device in the place of larger fumes and steam.

             And do not install in the place of the exhaust fan, door and window side 
             and larger bathroom water vapor .

8.Alarm Treatment

     When the combustible gas concentration in the air over to or exceed to the 
     alarm preset concentration, detector continue to alarm. You should make below treatment.
        1.Closed the pipeline valve.
        2.Open the window to make indoor air circulation.
        3.Blank off all the fire source, cut off all the commodities can produce sparks.
        4.Do not use the switch or power source.
        5.Check the gas leak and notify related department and specialized people.

9.Maintenance

     Use the carbon monoxide gas detector for a long time, and the gas convection window will have some oil adhesion, which affects 
     the sensitivity of air. It is recommended that the user clean the gas convection window with brush mixed a small amount of detergent 
    every three months (or depending on the pollution situation). Do not allow the clean out fluid to enter the machine body. After cleaning, 
    test the product again.

10.Notice

        1.It will occurs false alarm when the circuit is instability.
        2.Please make the product maintenance according to the manual indicated.
        3.It must make the test working every half year. Please maintain or change if it do not work.
        4.It can not make everything highly secure, only can reduce the accident occurs. Please use this product in proper way, raise 
           vigilance in daily life and enforce the safety precaution consciousness.