background image

Chapter 2. IR Remote Control

 

1. Basic function 

Users can use remote control to operate matrixes, the function of 
remote control key is the same as matrix front panel key (Please refer 
to chapter 1 for detailed instructions).   
Please refer to sections of menu operation for detailed operation 
method of remote control key. 

 

2. Camera function 

For the matrix with and has opened the video tracking function, users 
can use remote control to operate the cameras which connected to the 
matrix. The functions of camera operate as below: 

1) Camera control 

a. press the yellow button to enter the menu: 

 

Camera Control 

0

 

b. select a camera ID (1 to 8 buttons); 
c. use the following buttons to adjust the camera; 

Button

Function

Button

Function Button Function

 Left 

STATUS

Up 

Green 

Magnify

 Right 

CLOSE

Down Red 

Lessen 

d. press the “CANCEL” button to exit. 

 

2) Camera scan 

a. press the blue button to enter the menu: 

 

Camera Scan 

0

 

b. select a camera ID (1 to 8 buttons); 
c. use the following buttons to control the direction of the camera; 

Button

Function Button 

Function 

Frame scan   

(between preset 30 and 31) 

2 Auto 

cruise

scan 300

°

 

scan 180

°

d. press the “CANCEL” button to exit. 
 

The remote control can be used for all 

TAIDEN

 matrix main units with 

IR receipt function. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

10

Summary of Contents for TMX-0404SDI

Page 1: ...High Definition Digital Video Tracking Matrix Switcher Professional Matrix Switchers Installation and Operation Manual V 1 1 ...

Page 2: ...not responsible for any damage caused by improper use of this manual The equipment must be connected to earth This product conforms to the rules of the European directive 2004 108 EC If any detailed information needed please contact your local agent or TAIDEN service center in your region Any feedback advice and suggestion about the products is appreciated TAIDEN is the registered trademark of TAI...

Page 3: ...of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 15 Do not place the equipment on any uneven or unstable stand...

Page 4: ...ith the National Electrical or applicable local codes Power Disconnect Units with or without ON OFF switch have power supplied to the unit whenever the power cord is inserted into the power source however the unit is operational only when the ON OFF switch is in the ON position The power cord is the main power disconnect for all units WARNING To reduce the risk of fire or electric shock DO NOT exp...

Page 5: ...1 1 2 Installation and connection 2 1 2 1 Installation 2 1 2 2 Connection between Mixed Switcher and PC 2 1 2 3 Connection with input output devices 2 1 3 Setup and Operation 4 1 3 1 Menu setup 4 1 3 2 Switch operation 7 Chapter 2 IR Remote Control 10 Chapter 3 Communication protocol and control code 11 Chapter 4 Technical data 13 IV ...

Page 6: ...configuration and operation of High Definition Digital Video Tracking Matrix Switchers Chapter 2 IR Remote Control Introduction into the operation of IR remote control Chapter 3 Communication protocol and control code Detailed description of codes and their function Chapter 4 Technical data Mechanical and electrical details of the High Definition Digital Video Tracking Matrix Switchers This manual...

Page 7: ... root 5 IR receiving window Receives the IR signals from remote control make sure the remote control aims at the window 6 NETWORK indicator Indicator flashes if Matrix Switcher is connected with PC software 7 ACTIVE indicator Indicator will be turned on if Matrix Switcher executes switch instructions 8 POWER indicator Rear panel 9 TAINET interface 10 RS 422 485 interface 11 Video inputs 12 Video o...

Page 8: ...g Matrix Switcher supports various digital video signal sources including full HD 3G HD and SD As figure 1 4 Please use good quality Twisted Pair cable to connect input and output device i e RG59 and RG60 Control Interface Video Track Off COM RS 232 9 pin female D connector COM1 Baud rate 9600 data 8 bits stop 1 bit no parity check bit RJ45 To matrix PC software RS422 RS485 TAINET Invalidation Vid...

Page 9: ...Figure 1 4 Connection example for input and output devices to TMX 0808SDI Matrix Switcher 3 ...

Page 10: ...g switch and receiving command from central control system The buzzer ring can be setup off ON open OFF close 2 COM2 Baud rate SDI series Matrix Switcher has no COM2 port so this item can t be adjustable 1 Press MENU to enter setup menu and press Õ Ö until Setting prompts 2 Press MENU and press Õ Ö until Ring prompts 3 Press MENU to enter setup 4 Press Õ Ö to select parameter 5 Press MENU to confi...

Page 11: ... confirm Setting COM1 protocol Taiden COM1 protocol Taiden COM1 protocol Extron COM1 protocol Extron TMX 0808SDI Version 2 10 1 Press MENU and press Õ Ö until Setting prompts 2 Press MENU and press Õ Ö until Demo Switch Delay prompts 3 Press MENU to enter setup 4 Press Õ Ö to adjust parameter 5 Press MENU to confirm TMX 0808SDI Version 2 10 Setting DemoSwitchDelay 2 S DemoSwitchDelay 2 S DemoSwitc...

Page 12: ...ONY BRC Z330 SONY BRC300 SONY BRC700 Please select correct protocol according to actual device type 1 Press MENU and press Õ Ö until Setting prompts 2 Press MENU and press Õ Ö until Video Track Type prompts 3 Press MENU to enter setup 4 Press Õ Ö to select parameter 5 Press MENU to confirm Setting Video Track Type PELCO P1 Video Track Type PELCO P1 Video Track Type PELCO P2 Video Track Type PELCO ...

Page 13: ...nnel 4 Press Õ Ö to adjust input channel as 1 5 Press MENU to select output channel 6 Press Õ Ö to adjust output channel as 8 7 Press MENU to confirm and press EXIT twice TMX 0808SDI Version 2 10 Switch Video Switch Video 0 1 Switch OK Switch Video 1 1 Switch Video 1 8 Note Input channel and output channel number must be less than matrix type For example TMX 08xxSDI series can only input number 1 ...

Page 14: ... 10 Recall scene Recall scene 0 Switch OK 3 Recall scene 3 1 Press MENU and press Õ Ö until Save scene prompts 2 Press MENU to enter Save scene 3 Press Õ Ö to select scene number 3 4 Press MENU to confirm TMX 0808SDI Version 2 10 Save scene Save scene 0 Save scene OK 3 Save scene 3 1 Press MENU and press Õ Ö until Close prompts 2 Press MENU to enter Close menu 3 Press Õ Ö to select channel 2 4 Pre...

Page 15: ...ts 2 Press MENU to execute TMX 0808SDI Version 2 10 Demo switch Demo switch 1 Press MENU and press Õ Ö until Undo prompts 2 Press MENU to execute TMX 0808SDI Version 2 10 Undo Switch OK 1 Press MENU and press Õ Ö until Setting prompts 2 Press MENU to enter setup status Refer to section 1 3 1 for details TMX 0808SDI Version 2 10 Setting SyncSwitchDelay 0 ms 1 Press MENU and press Õ Ö until Status p...

Page 16: ... below 1 Camera control a press the yellow button to enter the menu Camera Control 0 b select a camera ID 1 to 8 buttons c use the following buttons to adjust the camera Button Function Button Function Button Function Left STATUS Up Green Magnify Right CLOSE Down Red Lessen d press the CANCEL button to exit 2 Camera scan a press the blue button to enter the menu Camera Scan 0 b select a camera ID ...

Page 17: ...9 Audio of input channel x1 switch to all output channels 0xd9 0xe6 x1 e9 Video and audio of input channel x1 switch to all output channels 0xd9 0xec 0x01 0x00 Close all output channels 0xd9 0xeb 0x03 0x00 Go through from all input channels to corresponding output channels 0xd9 0xed 0x02 0x00 Execute switch 0xd9 0xe7 0xe7 scene Save corresponding relation to scene 0 1 2 9 0xd9 0xe8 0xe8 scene Reca...

Page 18: ...de system unit to a EXTRON code system unit run EXTRON then the unit will only support code ends with 2 x1 All For example Input channel 3 switch to all output channels code is 3All 3 All Setup all channels one to one correspondence 1 1 2 2 3 3 8 8 4 All Close all output channels 5 x For example Input channel 5 switch to output channel 5 code is 5 6 x For example Close output channel 5 code is 5 7...

Page 19: ...Connectors 4 BNC female 8 BNC female Nominal level 0 8 V 7 Output level 0 5 V 1 6 Vp p Impedance 75 Ohm Return loss 15 dB 5 MHz to 1 5 GHz DC offset 100 mV with no offset at input Jitter 20 ps 30 ps HD 3G rate 40 ps 60 ps SD rate Rise and fall time 20 80 SD 600 ps HD 3G 100 ps Control Video track off COM RS 232 RS 232 9 pin female D connector COM1 Baudrate 9600 data 8 bits stop 1 bit no parity RJ4...

Page 20: ...eral spec Power supply 100 V AC 240 V AC 50 60 Hz Temperature Operating 0 C to 50 C storage 20 C to 70 C Humidity Storage and operating 10 to 90 Dimensions h w d mm 483 208 43 1U high full rack width Weight 2 7 kg Mean time between failures 30 000 hours ...

Page 21: ...www taiden com TAIDEN INDUSTRIAL CO LTD Copyright by TAIDEN Last Revision 09 2014 ...

Reviews: