3-4
3.4 Electric system calculation
3.4.1 For TPR-720A, TPR-820A, TPR-920A
Motor Part Name
Rated Power Capacity
Maximum Initiate Power
Main Motor
1.5kw
4.2kw
Elevating Motor
0.75kw
2.1kw
Coolant Pump Motor
0.1kw
0.28kw
Total Rated Power Capacity:
(1.5kw+0.75kw+0.1kw)=2.35kw…………………..(1)
Maximum Total Initiate Power Capacity:
(4.2kw+2.1kw+0.28kw)=6.58kw………………….. (2)
Transformer Rated Output Power Capacity for Control Circuits
Model
Item
100VA
Input
AC400V
±
±±
±
10% 1
∅
∅
∅
∅
Power Supply
Output
AC240V
±
±±
±
10% 1
∅
∅
∅
∅
Ambient Temperature
0°C To 55°C
S=KVA
P=KW
Pf
×
××
×
n = 0.75 (Correction Factors)
S=
KW
Pf
×
××
×
n(0.75)
P=
2.35Kw
0.75
=3.133KVA………………….. (1)
P=
6.58Kw
0.75
=8.773KVA………………….. (2)
Power Equipment Capacity=
3.8.773KVA
2
=5.935KVA