INSTALLATIONS
3-9
3.5 The Installation o f DT-2000NF Rack Mounted Series
3.5.1 Unpacking
Warning: When handling
cards, use local office procedures regarding
avoid electrostatic discharge (ESD) damage, including but not
limited to the following:
•
Use grounded wrist straps and connected to the equipment frame ground when
handling cards.
•
Store cards only in anti-electrostatic packaging provided by the factory.
3.5.2 Card Installation
•
Each shelf has a possible 16 slots.
•
Use the following instructions whenever installing a card into a slot:
(1)
Hold the card by the locking lever on the face plate, and carefully align card
with the connector on the shelf back plane.
(2)
Secure the card into place by pressing on the locking lever.
D T - 2 0 0 0 N
T R S - 3 2 M
Fig.3-9 Card insertion