OPERATING, MAINTENANCE
4-17
4.2.5. HDSL CONFIG
Table 4-3 HDSL CONFIG items and descriptions
UNIT EQUIP STATE
EQUIPPED
When set to be equipped, users are allowed
to set the Configuration.
UNEQUIPPED
When set to be unequipped, users are only
allowed to monitor the status.
SYSTEM TYPE
E1-R
Be Remote site with full E1 function.
E1-C
Be Central Office site with full E1 function.
E1-CF
Fractional E1 central Office site.
E1-RF
Fractional E1 remote site.
SET E1 CLOCK
CODIRECTIONAL (For E1-C only) Set the E1 clock to be Codirectional or
E1-C NETWORK
Central Office site Network or
E1-C INTERNAL
Central Office site Internal.
E1 SERVICE STATE
OOS
Select to Out-Of-Service to de-activate all
the E1 alarm detection.
IS
Select to In-Service to activate the E1 alarm
detection.
E1 FRAME FORMAT
UNFRAME
Set the E1 Frame Format to 2048 kbps
unstructured digital leased line.(D2048U)
FRAME+CRC
Set the E1 Frame to 2048 kbps structured
digital leased line.(D2048S) with CRC.
FRAME
Set the E1 Frame to 2048 kbps structured
digital leased line without CRC.
E1 BER THRESHOLD
10^-3 ~ 10^-9
Set the E1 BER Threshold ranging from 10^-
3 ~ 10^-9
Default setting is 10^-7
HDSL SERVICE
OOS
Select to Out-Of-Service to de-activate the
HDSL alarm detection.
IS
Select to In-Service to activate the HDSL
alarm detection.
Summary of Contents for DT-2000 Series
Page 6: ...CHAPTER 1 INTRODUCTION CONTENT 1 1 General Description 1 2 Specifications 1 3 Module List...
Page 7: ......
Page 15: ......
Page 26: ...UNIT DESCRIPTIONS 2 11 This page is intentionally left blank...
Page 27: ......
Page 29: ......
Page 41: ...3 12 INSTALLATIONS This page is intentionally left blank...
Page 42: ......
Page 69: ...4 26 OPERATING MAINTENANCE This page is intentionally left blank...