 Caution 

 

* Do not install the oil cooler where explosive dust or gas may be produced. 

(It may cause an explosion or a fire.) 

 

* Do not step on the oil cooler. 

 

(It may cause a breakdown or an injury.) 

 

* Do not install the oil cooler where it may directly contact with flame. 

 

(It may cause a fire.) 

 

 

* Do not install the oil cooler in a humid place. 

 

(It may cause an electric shock or a fire.) 

 

 

* Be sure to take sufficient space in front of the air inlet/outlet sides of the oil 

cooler. 

 

(Performance may decrease or it may cause a breakdown of the fan motor) 

 

  * Installation, operation, and maintenance must be done by a proper technician. 

 

(It may cause an electric leakage or an injury.) 

 *  Carry  out  wiring  work  safely  and  securely  in  accordance  with  the  electrical 

equipment standards and internal wiring rules. 

 

(A loose connection or a wrong connection may cause an electric shock or a fire.) 

 

 

1) Install the oil cooler securely on a firm and steady frame. 

Take sufficient space around the oil cooler for installation, inspection, cleaning, and maintenance. 

Especially,  be  sure  to  clear  of  obstacles  in  front  of  the  air  inlet/outlet  sides,  otherwise 

performance may decrease by the air quantity reduction. 

Minimize the vibration of the oil cooler during operation as much as possible. 

In case of large vibration, use rubber cushions to prevent it. 

 

8. Piping

 

1) Check the oil inlet and outlet before connecting the pipes. 

2) The pipe joint of the radiator is Rc threaded. 

Wrap the pipe tip with seal tape and screw into the joint. 

3) When connecting the pipes to the radiator, tighten the pipes within the recommended tightening 

torque range while holding the hexagonal part of the oil inlet/outlet with a wrench, etc. 

If the hexagon part is not held or is tighten with excessive torque, the radiator may be damaged. 

4) The radiator is made of aluminum. In case of connecting the pipes harder than aluminum, 

Summary of Contents for ATL-A Series

Page 1: ...ATL A SERIES OIL COOLER AIR COOLED TYPE INSTRUCTION MANUAL TAISEI KOGYO CO LTD No B11001562 Issued Nov 25 2019 Please make sure to read this manual completely before using this product...

Page 2: ...vent any injury or damage The graphic symbols shown in the Caution represent as follows Prohibited Unplug power cord Do as instructed without fail Do not touch Connect protective grounding wire Do not...

Page 3: ...Product Name 1 2 Model Identification 1 3 Specifications 1 4 Product Description 2 5 Transportation 2 6 Motor Wiring 3 7 Installation 8 8 Piping 8 9 Operation 9 10 Maintenance 10 11 Storage 11 Content...

Page 4: ...partially It may cause an injury if it is removed and used Do not use the fan motor in the other voltage and frequency except for rated value in the specifications It may cause an electric shock or a...

Page 5: ...03 P1 100V 50Hz 60 Hz 36W 31W 40 C 60 C RH Less than 95 ATL A A 03 P15 115V ATL A A 03 P12 120V ATL A A 03 P2 200V ATL A A 03 P22 220V ATL A A 03 P23 230V 4 Product Description This product is the Ai...

Page 6: ...an It may cause an electric leakage or an injury Carry out wiring work safely and securely in accordance with the electrical equipment standards and internal wiring rules A loose connection or a wrong...

Page 7: ...ut the fan motor lead wire and ground wire from the hole on the case Note Make sure that the fan blade does not hit the wires inside the case 2 As shown in the exploded view place the fan guard with t...

Page 8: ...ion panel It may cause an electric shock or an injury Installation operation and maintenance must be done by a proper technician It may cause an electric leakage or an injury Carry out wiring work saf...

Page 9: ...n the exploded view on page 7 Note The screw tightening torque should be within the range of 0 5N m 15 Remarks a Use a round pressure terminal b The maximum size of a round pressure terminal is 1 25 4...

Page 10: ...7 DIN connector exploded view Connection diagram of DIN connector Dimensional diagram of DIN connector...

Page 11: ...may cause an electric shock or a fire 1 Install the oil cooler securely on a firm and steady frame Take sufficient space around the oil cooler for installation inspection cleaning and maintenance Esp...

Page 12: ...may cause a breakdown Do not put your finger or any object into the fan motor It may cause an injury Keep away your hands or body from the oil cooler since it could be heated to a high temperature dur...

Page 13: ...water over the oil cooler housing It may cause a breakdown an electric leakage an electric shock or an early rust formation Before cleaning be sure to unplug the power cord or turn off the circuit bre...

Page 14: ...ding to the following procedures 11 1 Short time Storage 1 Keep the oil cooler in a clean and dry room 2 If storage place is outdoor or humid cover it completely with a vinyl sheet etc 11 2 Long time...

Reviews: