6 . S T O R A G E

If the oil filter is not used immediately, store it with particular attention
paid to the following.

(1) Keep it in a clean and dry room.
(2) If it is stored outdoors or in a humid place, cover it tightly with a vinyl

sheet or equivalent.

7 . I N S T A L L A T I O N

Caution

* Connect pipes oiltight.
* Never mount on or hang from the oil filter, or it may be damaged or

an injury may be suffered.

* Installation, operation, maintenance and checking must be performed

by skilled persons with expertise.
Unqualified persons may cause oil leaks or suffer an injury.

(1) Location and ambient conditions

Location: Indoors (where little dust raises,

water is not splashed on or there are no flammable)

Ambient temperature: 0℃ ~ 80℃

(2) Before connecting pipes, make sure of the locations of oil inlet and outlet.

Be sure that the drain plug of the housing faces down. The flow direction of

oil is arrow marked on the cover. Ascertain that the direction is correct.

(3) Connect pipes to the filter using care so that the housing is not excessively

stressed.

(4) When setting up pipe joints,screw a part of screw on a pipe into the entrance

of body① .

(5) When installing, allow sufficient space for maintenance work in future.

Be sure to provide an element allowance enough to enable easy replacement
below the housing.

8 . O P E R A T I O N

Caution

* Service pressure (including pressure variations) must not

exceed 21.0MPa{21.0kgf/cm }.

Use under any higher pressure may result in a damaged filter.

* The oil filter becomes very hot during operation.

Stay away from it to avoid burns.

Summary of Contents for TM

Page 1: ...ke sure that the user has a copy of this manual at hand for use as an operating guide Taisei Kogyo Co Ltd 6F Imaimitsubishi Bldg 3 53 11 Minamiotsuka Toshima ku Tokyo Japan Phone 81 3 6912 9922 F a x 81 3 6912 5921 No MF015 00 3 APR 28 2012 TM ...

Page 2: ...utions to be taken in case erroneous handling of the product may give rise to a dangerous situation and possibly result in a medium or minor injury or material damage are headed with Caution for particular attention These instructions must be strictly followed to prevent a serious accident that might otherwise occur C O N T E N T S 1 Product Identification 2 2 Model Code Description 2 3 Principal ...

Page 3: ... to Micro capacity application Micro capacity type is not applicable to Standard capacity application You must use the right indicator which is corresponded to the electric capacity 3 PRINCIPAL SPECIFICATIONS Permissible maximum pressure 21 0MPa Applicable fluid Mineral oils Note For phosphate and water glycol based hydraulic oils filters are different in material Service temperature range 0 90 0 ...

Page 4: ...5MPa 3 5kgf cm 2 Note that the oil filter equipped with a high pressure element 3CH 8CH 25CH have the relief valve passage blind plugged so that it has no relief valve Differential pressure type indicator optional Two types of optional indicators are available One is a visual type indicator I type whose indication turns red from green when it detects a pressure difference in filter element that ex...

Page 5: ... are no flammable Ambient temperature 0 80 2 Before connecting pipes make sure of the locations of oil inlet and outlet Be sure that the drain plug of the housing faces down The flow direction of oil is arrow marked on the cover Ascertain that the direction is correct 3 Connect pipes to the filter using care so that the housing is not excessively stressed 4 When setting up pipe joints screw a part...

Page 6: ...ntinued use of a clogged filter element causes the relief valve to open to let contaminants flow out of the oil filter resulting in a malfunctioning system 3 For filter paper elements semiyearly replacement is recommended to maintain their performance regardless of condition 9 2 Replacement Caution Stop the hydraulic unit and ascertain that the filter pressure is zero before replacing the oil filt...

Page 7: ...e In the case of wire gauze filter elements below 25 microns remove surface accumulations mostly by the above method and clean completely by ultrasonic cleaning without fail In the cleaning tank place the top and bottom of the filter element on the vibrator side alternately and clean While it depends on the capacity of the ultrasonic cleaning equipment and the amount of sludge on the element the c...

Page 8: ......

Reviews: