10.12
T805-04 Backplane
M805-00
30/04/95
Copyright TEL
10.3.2.3
Linking Details
The following tables contain the linking details for backplanes in a multi-rack system.
Note:
Rack-1 is defined as the first rack in a network. A new Group is formed for
each new network. The first rack of a network will have PL-1 unconnected
and PL-3 will be linked to the second rack in that network.
Rack-N is defined as the last rack in the network (and the last rack in its
Group) and will have PL-1 connected to the previous backplane. PL-3 will
be unconnected.
*See Section 10.3.2.3
Table 10.4 Linking details for a multi-rack network consisting
of N racks.
Table 10.5 Linking details for each "Group" of racks in a multi-
rack T805 Quasi-Synchronous network.
Rack-1 Of Network
(And Group)
Racks -2 To -N Of Network
Monitor Receiver
Audio From
Previous Rack*
No Monitor Receiver
Audio From Previous
Rack*
link 2-0A
link 2-0B
1-2
1-2
2-3
2-3
1-2
1-2
Rack-1 Of Network
(And Group)
Racks -2 To -N Of Network
link 3-0A
link 3-0B
1-2
1-2
1-2 (ADC-1) 2-3 (ADC-2)
1-2 (ADC-1) 2-3 (ADC-2)
link 3-10A
link 3-10B
1-2
1-2
1-2
1-2
link 4-0A
link 4-0B
1-2
1-2
2-3
2-3
link 4-10A
link 4-10B
1-2
1-2
1-2
1-2
link 6-0
1-2
2-3
First Rack & Other Racks
In Group Of 32
Last Rack In
Group Of 32
link 7A
link 7B
link 7C
2-3
1-2
1-2
1-2
2-3
2-3
Summary of Contents for T805
Page 16: ...4 2 ASP Card Operation M805 00 30 04 95 Copyright TEL ...
Page 44: ...7 18 Initial Programming Adjustment M805 00 30 09 96 Copyright TEL ...
Page 70: ...14 1 2 PCB Information M805 00 30 04 95 Copyright TEL ...
Page 89: ...Copyright TEL 30 09 96 M805 00 T805 Front Panel PCB Information 14 5 3 ...