TM8100/TM8200 Service Manual
Frequency Synthesizer Fault Finding
221
© Tait Electronics Limited
June 2006
Task 29 —
Repair PLL feedback
If both the maximum and minimum VCO frequencies are correct, then the
PLL feedback is suspect.
1.
Resolder
R542
in position (see
2.
Remove the
VCO
BOT
can.
3.
Replace the components
L510
(see
IC503
(see
Note
On A4 band radios there is no L510. Replace L5010 instead.
4.
Confirm that the fault in the radio has been removed. If it has, go to
. If it has not, replace the board and go to
.