TM8100/TM8200 Service Manual
Transmitter Fault Finding (40W/50W)
275
© Tait Electronics Limited
June 2006
Task 8 —
Check Temperature
Sensor
If the transmitter is being inhibited and the logic signal at the
D TX INH
test
point is active, a fault in the temperature sensor may be the cause.
1.
Enter the CCTM command
47
to check the temperature reading.
2.
Of the two numbers returned, the first is the temperature in degrees
celsius and should be about 25°C. If it is, go to
PA Driver and PAs” on page 280
. If it is not, go to
.
3.
If not already done, remove the
PAF
TOP
can.
4.
Check
D301
and the surrounding components — see
(UHF shown).
5.
“CODEC and Audio Fault Finding” on
. If a fault is found, repair it, confirm the removal of the
fault, and go to
. If the repair failed, replace