TM8100/TM8200 Service Manual
CODEC and Audio Fault Finding
403
© Tait Electronics Limited
June 2006
Task 16 —
Check CODEC 2
Device
If the DC offset measured in
is incorrect but there is no fault with
the auxiliary connector, check the CODEC 2 device.
1.
Remove the
CDC
TOP
can.
2.
Check the voltage at both ends of
R241
(see
3.
If the voltages are correct, go to
.
4.
Check for and repair any soldering faults around
IC205
, or else
replace IC205 (see
5.
Confirm the removal of the fault and go to
. If the repair failed, replace the board and go to
.
6.
Remove
R241
.
7.
Check the voltage at pin 3 of
IC205
(see
8.
If the above voltage is correct, go to
. If it is not, replace the
board and go to
.
9.
Check for and repair any soldering faults around
R241
and
IC205
(see
10.
Confirm the removal of the fault and go to
. If the repair failed, replace the board and go to
.
R241: 1.5V DC at both ends
pin 3 of IC205: 1.5V DC
Summary of Contents for TM8235
Page 1: ...TM8100 mobiles TM8200 mobiles Service Manual MMA 00005 04 Issue 4 June 2006...
Page 10: ...10 TM8100 TM8200 Service Manual Tait Electronics Limited June 2006...
Page 62: ...62 Description TM8100 TM8200 Service Manual Tait Electronics Limited June 2006...
Page 148: ...148 Disassembly and Reassembly TM8100 TM8200 Service Manual Tait Electronics Limited June 2006...
Page 162: ...162 Servicing Procedures TM8100 TM8200 Service Manual Tait Electronics Limited June 2006...
Page 178: ...178 Interface Fault Finding TM8100 TM8200 Service Manual Tait Electronics Limited June 2006...
Page 258: ...258 Receiver Fault Finding TM8100 TM8200 Service Manual Tait Electronics Limited June 2006...
Page 446: ...446 Spare Parts TM8100 TM8200 Service Manual Tait Electronics Limited June 2006...