TM8100/TM8200 Service Manual
Frequency Synthesizer Fault Finding
227
© Tait Electronics Limited
June 2006
9.8
Power Supply for FCL
Fault-Diagnosis
Stages
Indications of a fault in the FCL will have been revealed by the initial checks
in
and the PLL checks in
. In the latter case a fault with the reference frequency
input from the FCL to the PLL will imply that the FCL is suspect. Fault
diagnosis of the FCL is divided into four stages:
■
check power supply
■
check VCXO and TCXO outputs
■
check signals at TP501 and TP502
■
check VCXO and CODEC circuitry.
The checking of the power supply is given in this section in
below.
The remaining three stages are covered in
respectively. The test and
measurement points for diagnosing faults in the FCL are summarized in
.
Summary of Contents for TM8235