TM8100/TM8200 Service Manual
Transmitter Fault Finding (25W)
337
© Tait Electronics Limited
June 2006
12.
Repair any fault, confirm the removal of the fault, and go to
. If the repair failed or no fault could be found,
replace the board and go to
.
Task 8 —
Check Temperature
Sensor
If the transmitter is being inhibited and the logic signal at the
D TX INH
test
point is active, a fault in the temperature sensor might be the cause.
1.
Enter the CCTM command
47
to check the temperature reading.
2.
Of the two numbers returned, the first is the temperature in degrees
celsius and should be about 25°C. If it is, go to
PA Driver and PAs” on page 342
. If it is not, go to
.
3.
If not already done, remove the
PAF
TOP
can.
4.
Check
D301
and the surrounding components — see
5.
“CODEC and Audio Fault Finding” on
. If a fault is found, repair it, confirm the removal of the
fault, and go to
. If the repair failed, replace
the board and go to
Summary of Contents for TM8235
Page 1: ...TM8100 mobiles TM8200 mobiles Service Manual MMA 00005 04 Issue 4 June 2006...
Page 10: ...10 TM8100 TM8200 Service Manual Tait Electronics Limited June 2006...
Page 62: ...62 Description TM8100 TM8200 Service Manual Tait Electronics Limited June 2006...
Page 148: ...148 Disassembly and Reassembly TM8100 TM8200 Service Manual Tait Electronics Limited June 2006...
Page 162: ...162 Servicing Procedures TM8100 TM8200 Service Manual Tait Electronics Limited June 2006...
Page 178: ...178 Interface Fault Finding TM8100 TM8200 Service Manual Tait Electronics Limited June 2006...
Page 258: ...258 Receiver Fault Finding TM8100 TM8200 Service Manual Tait Electronics Limited June 2006...
Page 446: ...446 Spare Parts TM8100 TM8200 Service Manual Tait Electronics Limited June 2006...