2
Setting the differential time (td)
Press the [
SET
.] key
to select [
td
] .
Key Operation
TEMP Display
Example
: Changing the differential time from
5
to
30
.
After soldering, the tip temperature may increase to higher than the set temperature
depending on the tip type or the kind of work. (Overshoot)
“Overshoot” will often occur when using the
RX-85HSRT, but “Overshoot” can be con-
trolled by setting the parameters.
4
Press down the [
SET
.] key
for over 3 seconds.
3
Press the [
UP
] key to
set to 30.
Tip type
Differential time
RX-80HRT
series
5
RX-85HRT
series
5
RX-85HSRT
series
30
Standard of the differential time
Returns to the set
temperature display.
Setting completed
Displays
alternately
Displays
alternately
Displays
alternately
4-8
Control function for overshooting
1
Press and hold the
key
for over 3 seconds continuously.