background image

TAIYO ELECTRIC IND.CO.,LTD.

20

TAIYO ELECTRIC IND.CO.,LTD.

21

2

Setting the differential time (td)

Press the [

SET

.] key 

to select [

td

] .

Key Operation

TEMP Display

Example

 : Changing the differential time from 

5

 to

 30

After soldering, the tip temperature may increase to higher than the set temperature 
depending on the tip type or the kind of work. (Overshoot)

“Overshoot” will often occur when using the 

RX-85HSRT, but “Overshoot” can be con-

trolled by setting the parameters.

 4-8 Control function for overshooting 

 

(Each soldering unit can be set separately)

4

Press down the [

SET

.] key of 

soldering unit you changed for 
over 3 seconds.

3

Press the [

DOWN

] key 

to set to 30.

1

Press down the [

SET.

] key of 

soldering unit you desire for 
over 3 seconds. 

Tip type   

Differential time

 RX-80HRT

 series

5

 RX-85HRT

 series

5

 RX-85HSRT

 series

30

Standard of the differential time

Returns to the set 
temperature display.

Setting completed

Displays

alternately

Displays

alternately

Displays

alternately

RX-822AS英文取説_2015_03.indd   21

2015/03/20   14:45

Summary of Contents for Goot RX-822AS

Page 1: ...ns in this manual and use the soldering station properly and only for what it is intended you will enjoy years of safe reliable service Thank you again for buying a goot soldering station WARNING Before using the soldering station read the Operation Manual Failure to follow the safety precautions and instructions in this man ual could result in serious injury and property damage OPERATION MANUAL K...

Page 2: ...d all parts of this manual MODEL RX 822AS Voltage 110 120 220 240V AC Power Consumption 220 260W Soldering Iron Voltage Wattage RX 85GAS Soldering unit 1 side 24V AC 150W RX 80GAS Soldering unit 2 side 24V AC 72W Temperature Setting Range 50 450 C 122 842 F Dimensions Control Unit 194 L X 116 W X 105 H mm RX 85GAS Soldering unit 1 side 174mm with RX 85HRT 5D w o cord bushing RX 80GAS Soldering uni...

Page 3: ... Start Time CT 17 Setting the Sleep Sensitivity DIF 18 4 6 Setting the Shutdown Function 19 4 7 Setting the Temperature Range for the Alarm 20 4 8 Control Function for Overshooting 21 4 9 Setting the Alarm Sound 22 4 10 Setting the Temperature Scale Display 23 4 11 Key Lock Function 24 Setting and Releasing the Key Lock 24 Changing the Code Number 25 Resetting the Code Number 26 4 12 How to Restor...

Page 4: ... Use the hole of the sponge for better cleaning Alternatively push the soldering iron tip in and out of the brass wool a few times Stab not swipe Soldering Iron Stand ST 21 Instructions INSTRUCTION FOR USE Front Opening Adjusting Screws Heat Resistant Sponge ST 53SP Brass Wool ST 40BW ST 21MS To avoid rust do not pour water on the brass wool Sponge tray and hold ing flange of the front opening are...

Page 5: ...T series 7 Easy to replace tip without using tools PAT Slide change tip No tools or heat resis tance pads needed 8 Thick iron plating for lead free soldering All tips have a thick iron plating to slow ero sion caused by lead free soldering 9 Key Lock function PAT Tamper proof keypad lock using a pass word No tools or cards are needed 10 Sleep function PAT The control unit automatically lowers the ...

Page 6: ... below are included and that the soldering station functions properly before throwing away the packaging 2 2 Unpacking RX 822AS INSTRUCTION MANUAL KEY LO CK RX 822 HE AT SL EE P 1 TE MP C A S HE AT SL EE P 2 TE MP C DU AL PO RT SO LD ER ING ST AT ION 2 1 Operation Manual Soldering See instruction p 4 Iron Stand ST 21 Control Unit Power Cord Soldering Unit RX 80GAS Soldering Unit RX 85GAS ...

Page 7: ...Sold separately Rib to prevent inserting in the RX 80GAS soldering unit Check the direction of the tip before inserting 1 0 KEY LOCK RX 822 HEAT SLEEP 1 TEMP C AS HEAT SLEEP 2 TEMP C DUAL PORT SOLDERING STATION 2 1 Operation Panel Slide Lever Grip Rubber Adapter Ring Soldering Unit Connector Power Cord Socket With built in replacement fuse Power Switch Output Terminal for Soldering unit 2 72W Outp...

Page 8: ...when it is reached 4 ALARM lamp to the right of the last digit in the temperature display Flashes when the tip temperature is within the DIF range Turns off when the tip temperature is out of the DIF range Flashes when the tip temperature is out of the upper and lower tempera ture limits 5 KEY LOCK lamp Flashes while setting the Key Lock function Flashes when the unit is in Key Lock mode 6 KEY LOC...

Page 9: ...ldering unit RX 80GAS 72W Soldering unit RX 85GAS RX 80GAS 150W 72W RX 80HRT Series Sold separately 72W integrated heater RX 85HRT RX 85HSRT Series Sold separately 150W high power integrated heater Output Terminal for Soldering unit 2 72W Output Terminal for Soldering unit 1 150W 72W KEY LOCK RX 822 HEAT SLE EP 1 TEMP C A S HEAT SLE EP 2 TEMP C DUAL PO RT SO LD ER ING ST AT ION 2 1 ...

Page 10: ...e the soldering station should be stored in a dry and locked place Keep out of the reach of children 5 USE FOR THE RIGHT JOB This soldering station is an electrical tool used to solder parts and melt solder Do not use the soldering station for any other purpose For example The soldering station should never be used to warm water or other liquids 6 WEAR PROPER APPAREL SAFETY GLASSES GLOVES AND MASK...

Page 11: ... with the soldering station If this stand is not used the plastic parts adapter ring and or soldering unit housing of the soldering iron unit could become damaged Position the soldering iron stand on a flat work surface bench Follow instructions included with the soldering iron stand to assemble it 10 CONCERNING THE TIP Allow the tip to cool naturally Never use any other method to cool it down For...

Page 12: ...CK key KEY LOCK tPN Calibration of the Tip Temperature 4 3 cAL Calibration Function 4 4 SSt Sleep Temperature 4 5 ct Sleep Start Time 4 5 dIF Sleep Sensitivity 4 5 SUt Shutdown Start Time 4 6 H Alarm for Upper Temperature Limit 4 7 L Alarm for Lower Temperature Limit 4 7 td Overshooting Control 4 8 bUZ Alarm Sound 4 9 c F Temperature Scale Display 4 10 Press down for over 3 seconds 4 Operating Ins...

Page 13: ...d Key Operation TEMP Display Press the SET key of soldering unit you changed Note If nothing is pressed for 30 seconds during setting the tempera ture the temperature display will record the new data and the display will return to the normal conditions The set temperature should be set at 50 C 90 F higher than the sleep temperature see the section 4 5 otherwise you will not be able to set the set ...

Page 14: ...RT 1C 4 RX 80HRT 2C 4 RX 80HRT 3C 2 RX 80HRT 3BC 1 RX 80HRT 4C 1 RX 80HRT BM 1 RX 80HRT 2CD 4 RX 80HRT 3CD 2 RX 80HRT 4 7C 0 MODEL TIP NO RX 85HRT B L2 RX 85HRT 2BC L1 RX 85HRT 3BC L1 RX 85HRT 5BC L1 RX 85HRT 7BC L1 MODEL TIP NO RX 85HRT 3D L1 RX 85HRT 5D L1 RX 85HRT 7D L1 RX 85HRT 6K L1 MODEL TIP NO RX 85HSRT B L2 RX 85HSRT 1 6D L1 RX 85HSRT 2 4D L1 RX 85HSRT 3 2D L1 MODEL TIP NO RX 85HSRT 2BC L1...

Page 15: ... or The RX 822AS can be calibrated using a tip thermometer Generally speaking when measuring the tip temperature of the RX 822AS with a standard tip thermometer the measured temperature will usually be lower than that of the actual tip temperature displayed on the RX 822AS control unit display This could be because the tip is not coming into contact properly with the sensor of the tip thermometer ...

Page 16: ...y will alternate between SLP and the temperature To use sleep function manually during operation for soldering unit 1 press down the UP key for over 1 second and for soldering unit 2 press down the DOWN key for over 1 second Active Sleep Function Key Operation TEMP Display 3 Press the DOWN key to set to 150 Press the SET key to select SST 1 4 Press down the SET key of soldering unit you changed fo...

Page 17: ...he sleep function will be turned off and the SLEEP lamp will turn off 1 4 Press down the SET key of soldering unit you changed for over 3 seconds Press down the SET key of soldering unit you desire for over 3 seconds Each soldering unit can be set separately 2 1 or Setting completed Returns to the set temperature display Setting the Sleep Start Time CT Unit mins Displays alternately Displays alter...

Page 18: ...y value DIF is set too low there is a possibility that the sleep function will not be activated even after passing the set sleep start time If this happens increase the sleep sensitive value 1 4 Press down the SET key of soldering unit you changed for over 3 seconds Press down the SET key of soldering unit you desire for over 3 seconds Each soldering unit can be set separately 2 1 or Setting the S...

Page 19: ...IF Sensitivity When using together with Sleep function Shutdown Function SUT Power OFF Soldering tip temperatrue Set temperature Power ON Time Operation DIF DIF Sensitivity Shutdown start time Key Operation TEMP Display When the SUT Shutdown Start Time value is set to 0 the shutdown function is OFF When the unit enters shutdown Sdn and the temperature are displayed alternately When the temperature...

Page 20: ...s alternately Displays alternately Displays alternately Displays alternately Upper Temperature Limit Lower Temperature Limit Lower Temperature Limit This function warns the operator with an alarm when the tip temperature exceeds the set parameters The diag onal lines in the illustration on the right show when the alarm will sound Both the upper and lower limit alarms can be set from 3 C to 100 C T...

Page 21: ...5HSRT but Overshoot can be con trolled by setting the parameters 4 8 Control function for overshooting Each soldering unit can be set separately 4 Press down the SET key of soldering unit you changed for over 3 seconds 3 Press the DOWN key to set to 30 1 Press down the SET key of soldering unit you desire for over 3 seconds Tip type Differential time RX 80HRT series 5 RX 85HRT series 5 RX 85HSRT s...

Page 22: ...P Display Press down the SET key for over 3 seconds 4 9 Setting the Alarm Sound 3 Press the DOWN key to select big biG small SmL or off oFF 1 Press down either of the SET keys for over 3 seconds 2 1 or Returns to the set temperature display Setting completed Displays alternately Displays alternately Displays alternately Displays alternately Shipping Default Setting BIG ...

Page 23: ...hipping Default Setting Celsius C The temperature can be displayed in either Celsius or in Fahrenheit 4 10 Setting the Temperature Scale Display Key Operation TEMP Display Displays alternately Returns to the set temperature display Setting completed Displays alternately Displays alternately Displays alternately The temperature scale on the operation panel is printed in C If you use Fahrenheit eith...

Page 24: ...er from 001 to 999 When the code number is set correctly the number will flash 5 times If an incorrect code number is input the display will show NG and return to the initial display 4 11 Key Lock Function 1 3 Press the KEY LOCK key Key Operation TEMP Display 2 Input the desired code number using the UP DOWN keys Press the KEY LOCK key The KEY LOCK is set and released by the same procedure Setting...

Page 25: ... pres ent code number Press the KEY LOCK key Changing the Code Number 2 Press down the KEY LOCK key for over 3 seconds 4 Press the KEY LOCK key 5 Input the desired new code number using the UP DOWN keys Example When changing the code number from 123 to 234 2 2 2 2 2 2 1 1 1 1 1 1 Returns to the set temperature display Setting completed Displays flashes ...

Page 26: ... change the settings Therefore this manual should be given to authorized person nel only Resetting the Code Number 1 4 Press the KEY LOCK key Key Operation TEMP Display 3 Input 471 using the UP DOWN keys Press the KEY LOCK key 2 1 Press down the SET KEY1 key and UP key simultaneously for over 3 seconds Flashes 2 times 2 2 2 2 1 1 1 1 Setting completed Flashes 5 times Returns to the set temperature...

Page 27: ...re shown above the code num ber cannot be reset When you want to delete the code numbers please follow the procedure Resetting the Code Number 4 12 How to Restore Default Settings 1 Key Operation TEMP Display 2 All settings are restored to the shipping default How to Restore Default Settings Flashes 5 times 2 Press down these following keys simultaneously for over 5 sec onds while the preset tempe...

Page 28: ... to a different type of tip be sure to input the Tip No Refer to page 14 Since the heater is integrated into the tip replacement of only the heater or the tip is not possible Slide Lever A KEY LOCK RX 822 HEAT SLEEP 1 TEMP C AS HEAT SLEEP 2 TEMP C DUAL PORT SOLDERING STATION 2 1 4 To heat the tip press the SET key of the relevant tip 5 Maintenance WARNING The tip can be replaced without turning th...

Page 29: ...2 How to Change the Grip Rubber 1 Place a slotted screwdriver in the slot to pull out the fuse box 2 Press both sides of the fuse box to remove it A spare fuse is stored on the other side of the fuse box Therefore turn the fuse box over or to the side to replace the fuse 5 3 How to Change the Fuse Press and pull Pull out with a slotted screwdriver Pull out with a slotted screwdriver Press and pull...

Page 30: ...r of solder is necessary The tin surface of a lead free soldering iron oxidizes easily Coating it with solder reduces oxidation levels Oxidation starts as soon as the tool is plugged in and begins to heat When operation is completed tin the tip with solder before turning the power off This protects the tip from oxidation when it starts heating up the next time it is in use A lead free soldering ir...

Page 31: ...ollowing checklist Will not switch ON Check that the power cord is plugged in Check that the fuse is not blown The soldering iron tip will not heat up Check that the heater is not damaged Error message Cause Countermeasure The sensor or cord is damaged Replace the tip or soldering unit This message is also displayed when changing the tip but this is not an error Press any key on the panel Memory e...

Page 32: ...ting to use the RX 85HRT series tips in the RX 802AS will result in damaging the RX 802AS because the electric current will exceed the capacity of the RX 802AS RX 85HRT B RX 85HRT 2BC RX 85HRT 3BC RX 85HRT 5BC 11 5 4 R 0 6 45 2 5 11 5 3 5 45 11 5 5 6 45 11 5 RX 85HRT 7BC RX 85HRT 3D RX 85HRT 5D RX 85HRT 7D 7 11 5 8 45 3 11 5 1 5 5 5 11 5 1 5 7 5 11 5 7 1 5 8 2 RX 85HRT 6K 14 6 3 45 9 0 RX 85HSRT B...

Page 33: ... 3 45 φ 4 7 10 3 6 RX 80HRT 3BC RX 80HRT 0 5C RX 80HRT 1C RX 80HRT 2C φ 4 7 45 3 10 5 φ 4 7 0 5 9 60 1 φ 4 7 10 3 60 φ2 45 φ 4 7 11 5 5 RX 80HRT 2CD RX 80HRT 3C RX 80HRT 3CD RX 80HRT 4C 45 φ2 11 5 1 2 2 φ3 45 φ 4 7 11 5 5 5 φ3 2 3 45 11 5 φ4 φ 4 7 12 6 45 RX 80HRT 4 7C RX 80HRT 0 8D RX 80HRT 1 2D RX 80HRT 1 6D φ4 7 45 8 5 5 φ 4 7 10 3 0 4 φ 0 8 φ 4 7 10 3 0 4 φ1 2 φ 4 7 10 5 0 5 φ1 6 3 2 RX 80HRT ...

Page 34: ... port 1 and 2 72W 2 Soldering Iron Stand ST 21 3 Soldering Iron Stand Sponge ST 53SP Replacement sponge for ST 21 4 Soldering Iron Stand Cleaner ST 40BW Replacement Brass shaving for ST 21 2pcs set Four different colors available Handy to differentiate stations being used for different tasks in the same workspace Grip Rubber Selection Grip rubber gray RX 80RB Anti Static Grip rubber black RX 80RB ...

Page 35: ...p Number tPn 0 4 L1 L3 1 Temperature Calibration cAL 50 50 0 Sleep Set Temp SSt 0 Pt 50 200 Sleep Timer ct 0 00 999 Minute 5 Sleep Sensitivity diF 0 0 20 0 2 0 Shutdown Start time SUt 0 999 Minute 60 Upper Limit H 3 100 50 Lower Limit L 3 100 50 Differential Time td 0 100 cyc 5 Buzzer Sound BIG SML OFF BIG Temperature Scale c F c 9 Parameters ...

Page 36: ...OLDERING EQUIPMENT AND ACCESSORIES TAIYO ELECTRIC IND CO LTD Customer service Contact your nearest distributor goot is a registered trademark of TAIYO ELECTRIC IND CO LTD Printed in Japan A1240RX00 MARCH 2015 AOB Website www goot co jp E mail info goot co jp ...

Reviews: