8
Change the rotating direction of the electric
motor by inverting the poles on the plug.
RCA 380 E:
Connect the RCA 380 E to the thee-phase electric
power source:
Nominal voltage: 400 V / 50 Hz
Minimum Power Cable Size: 4 mm²
Plug: 32A-CCE 3P+N+E 400 V
Nominal Current of the Main Fuses: 32 A
Connection Power: 21,2 kW
Warning!
Before completing the connection of the machine
it is necessary to check the rotating direction of
the cutting chain and/or electric motor.
Wrong
rotating direction can cause damages to the oil
pump.
3.1. DISCHARGE CONVEYOR ASSEMBLY (in case of separate delivery)
Hydraulically driven discharge conveyor is also a component part of the firewood processor.
Place the discharge conveyor on the ground and move it closer to connecting spot.
Slide the discharge conveyor on the supporting forks and secure it with two screws (1-Figure: 3).
Fasten the lifting package by fixing rope pulleys to their position (2-Figure: 4).
Use the hand winch (3-Figure: 3) to lift the discharge conveyor slightly above the desired height and
attach the carrying chain (4-Figure: 3).
Loosen the wire rope, so that the weight of discharge conveyor is distributed between the wire rope and
carrying chain (4-Figure: 3).
Connect the hydraulic connectors (a & b).